SMITHS FALLS RISE AT THE FALLS

TOWN OF SMITHS FALLS WATER POLLUTION CONTROL PLANT

MONTREAL DISTRICT OF WATER SERVICE

2021 PERFORMANCE REPORT
Environmental Compliance Approval Number 5671-AE7HFT


March 31<sup>st</sup>, 2022

Ministry of the Environment Conservation & Parks Ottawa District Office, Eastern Region 2430 Don Reid Drive Ottawa, Ontario K1H 1E1

Attention Mr. Charlie Primeau

Dear Mr. Primeau,

Please find enclosed the Annual Performance Report and other supporting documents for the Smiths Falls Water Pollution Control Plant (WPCP), Works No.120000890 as per the Amended Environmental Compliance Approval Municipal and private Sewage Works Number 5671-AE7HFT January 11, 2017, prescribed by Condition 11 Subsection (4).

The Town of Smiths Falls is the owner and operator of the WPCP. The facility operated under the responsibility of Jason Barlow, Manager Water/Wastewater Treatment ORO whose office is located at 43 Abbott Street North, Smiths Falls, and can be contacted at 613-283-4124 ext. 5501 or faxed at 613-284-0427.

Regards,

Sarah E. Cooke Water and Wastewater Compliance Coordinator Tel: 613-283-4124 ext. 5502 Email: <u>scooke@smithsfalls.ca</u>

cc. Brenda Beaudoin, Water Inspector cc. Jason Barlow, Manager Water/Wastewater Treatment


Executive Summary

The enclosed Annual Performance Report is prepared in accordance with Amended Environmental Compliance Approval (ECA) number 5671-AE7HFT, Condition 11 Reporting Subsection (4) for the Town of Smiths Falls Water Pollution Control Plant (WPCP) for submission to the Ministry of Environment Conservation and Parks (MECP). The secondary purpose of this 2021 Performance Report is to keep the Owner (Council) informed regarding the general operation, maintenance and, facility compliance regarding solids and liquid handling and disposal as per the ECA. Each year it is a requirement that the owner prepares and submits an annual Performance Report for the previous calendar year and must contain the following information:

a) A summary and interpretation of all monitoring data and a comparison to the effluent limits in condition 7 in the Environmental Compliance Approvals (ECA), including an overview of the success and adequacy of the Works;

b) A description of any operating problems encountered and corrective actions taken;

c) A summary of all maintenance carried out on any major structure, equipment, apparatus, mechanism or thing forming part of the Works;

d) A summary of any effluent quality assurance or control measures undertaken in the reporting period;

e) A summary of the calibration and maintenance carried out on all effluent monitoring equipment;

f) A description of efforts made and results achieved in meeting effluent objectives of Condition 6.

g) A tabulation of quantity of sludge generated in the reporting period, an outline of anticipated quantities to be generated in the next reporting period and a summary of the locations to where the sludge was disposed;

h) A summary of any complaints received during the reporting period and any steps taken to address the complaints;

i) A summary of all by-pass, spill or abnormal discharge events;

j) A copy of all Notice of Modifications submitted to the Water Supervisor as a result of Schedule B, Section 1, with a status report on the implementation of each modification;

k) A report summarizing all modifications completed as a result of Schedule B, Section 3; and

l) Any other information the Water Supervisor requires from time to time.


In addition, this Annual Performance Report must be forwarded to the MECP no later than March 31, 2022. The WPCP must comply with all the requirements, criteria contained in the ECA, along with all Acts, Regulations, and F-Series Procedures made concerning operation of facilities, licensing of facilities, licensing of operators and Legislation that pertains to the Sustaining of Water and Sewerage Facilities.


Table of Contents

Executive Summary............................................................................................................ 3 1.0 Introduction............................................................................................................. 7 2.0 Facility and Process Overview...................................................................................... 7 2.1 Inlet Sewers............................................................................................................. 7 2.2 Head Works Building and Preliminary Treatment ........................................................... 7 2.3 Primary Treatment.................................................................................................... 8 2.4 Biological and Secondary Treatment............................................................................ 8 2.5 Tertiary Treatment ................................................................................................... 8 2.6 Disinfection & Outfall ................................................................................................ 8 2.7 Solids Handling ........................................................................................................ 9 2.8 Combined Sewer Overflow Tank ................................................................................. 9 3.0 Environmental Compliance Approval & Licensing..........................................................10 4.0 Monitoring Data ......................................................................................................10 4.1 Performance of Effluent Quality Assurance or Control Measures......................................11 4.2 Meeting Final Effluent Limits & Objectives ...................................................................11 5.0 Performance of Secondary Treatment By-pass Events...................................................12 6.0 Operational Problems & Corrective Actions..................................................................13 7.0 On Call ..................................................................................................................13 8.0 Performance of all Maintenance .................................................................................13 8.1 Centre St Pumping Station........................................................................................14 9.0 Performance of Verification and or Maintenance on Effluent Monitoring Equipment ............14 10.0 Sludge Generation...................................................................................................15 11.0 Summary Complaints...............................................................................................15 12.0 Ministry of Environment Conservation & Parks Communal Sewage Inspection Report.........15 13.0 Waste Received from Outside Smiths Falls ..................................................................15 14.0 Municipal Utility Monitoring Program (MUMPs) Report ...................................................15 15.0 Operator Licenses....................................................................................................16 16.0 Notice of Modifications (Limited Operational Flexibility)....................................................16


APPENDICES

Appendix A – Environmental Compliance Approval (ECA) #5671-AE7HFT (page 1 to 32)

Appendix B – Monitoring Data and Comparison to Effluent Limits (page 1 to 5)

Appendix C – Maintenance Records (page 1 of 24)

Appendix D – Solids Handling (page 1 of 3)

Appendix E – MUMPs Reports (page 1 to 25)

Appendix F – Operator Licenses (page 1 of 2)

Appendix G – Notice of Modifications (page 1 of 5)


1.0 Introduction

1.0 Introduction

This Annual Performance Report is for the period from January 1<sup>st</sup> to December 31<sup>st</sup> 2021 which is a legislative requirement under Condition 11 (4) of C of A number 5671-AE7HFT. This Annual Performance Report must be forwarded to the Ministry of Environment Conservation and Parks (MECP) no later than March 31<sup>st</sup>, 2022.

$$ 1^{\mathrm{st}} $$

$$ 31^{\mathrm{st}} $$

$$ 31^{\mathrm{st}} $$

2.0 Facility and Process Overview

2.0 Facility and Process Overview

The Smiths Falls Water Pollution Control Plant (WPCP) is responsible for providing wastewater collection and treatment from industrial, commercial and residential users within the limits of the Town of Smiths Falls, as well as Atironto subdivision in Montague Township. The wastewater is collected in sanitary and combined sewer pipes that is conveyed by gravity and or pumped to the WPCP. A total of 2,832,833 cubic meters (m<sup>3</sup>) of wastewater was treated in 2021.

$$ (m^{3}) $$

The WPCP is a Class IV nitrifying tertiary treatment activated sludge plant with a rated capacity of 14,700 cubic meters per day (m<sup>3</sup>/d). As such, the facility consists of a raw sewage lift station (head works building) including screening and grit removal/classification, primary treatment, secondary treatment including nitrification which removes nitrogen by a nitrification/denitrification process. The plant also has chemically assisted phosphorus removal, tertiary filtration and effluent disinfection by ultraviolet light irradiation (UV). Primary and thickened waste activated sludge is dewatered, dried and pelletized. The final product is sold for off-site reuse.

$$ (m^{3}/d) $$

2.1 Inlet Sewers

2.1 Inlet Sewers

The inlet sewers consist of one 600 mm diameter gravity sewer from the river crossing downstream at Old Slys Locks and one 900 mm diameter gravity sewer from the Highway 43 trunk sewer to the inlet sewer described above. Both of these collectors combine into a 1200 mm diameter gravity sewer which discharges into the wet well in head works.

2.2 Head Works Building and Preliminary Treatment

The head works building contains a 60 foot deep wet well where raw sewage is pumped (lifted) by three (3) sewage lift pumps up to the bar screens. There are two (2) additional sewage lift pumps onsite as backup pumps should one or more primary sewage lift pumps fail. Screening units consists of two (2) parallel bar screen channels which screen large suspended or floating solids and materials from the raw sewage to prevent plugging and damage to equipment.

Grit removal is accomplished by using tea cups which use a vortex action that will cause the heavier particles of grit and sand to separate out of the wastewater which then flows to the primary tanks. The grit is then pumped to a bin for off-site disposal.

2.3 Primary Treatment

2.3 Primary Treatment

The wastewater flows by gravity from the head works building to the primary clarifiers which consists of two (2) parallel rectangular clarifiers or tanks. The clarifiers consist of a chain and flight system which moves solids that have settled to the bottom of the clarifiers. These solids are later removed by processing into pellets. Floatables are skimmed from the surface and later landfilled.

2.4 Biological and Secondary Treatment

2.4 Biological and Secondary Treatment

The Biological and Secondary treatment occurs when primary treated wastewater is discharged into two (2) aeration basins, activated sludge (return activated sludge RAS) is mixed with the wastewater. Micro-organisms in the sludge provide biological treatment by consuming the colloidal and dissolved solids. A coagulant is added to the wastewater prior to wastewater entering the secondary clarifiers. This coagulant is added to help in the removal of phosphorus.

2.5 Tertiary Treatment

2.5 Tertiary Treatment

Tertiary treatment is an advanced wastewater treatment process which further removes nutrients like phosphorus and a higher percentage of suspended solids by sand filtration from the effluent.

2.6 Disinfection & Outfall

2.6 Disinfection & Outfall

Disinfection of the final effluent is provided by two (2) in series banks of ultraviolet (UV) light irradiation. The use of UV lights is used to irradiate the pathogenic micro-organisms in the effluent prior to discharging to the outfall. The final effluent is discharged through a 1,050 mm diameter outfall sewer pipe to the receiving water body which is the Rideau River.


2.7 Solids Handling

2.7 Solids Handling

Sludge from the primary and secondary treatment processes are pumped into one of two (2) 75 m<sup>3</sup> underground sludge storage tanks, the two tanks equalize through a common connection. The sludge is conveyed from the storage tanks to a belt filter press. The press produces a sludge cake with a minimum solids concentration of 18 - 22%. The dewatered sludge is fed to a single train sludge dryer and pelletizer process to produce a granulated dried sludge at a solids concentration of 94%. The sludge pellets are recognized as a fertilizer product by the Canadian Food Inspection Agency and are regulated under the Federal Fertilizer Act. These pellets are sold to TerraPure Environmental or area farmers and, as such the marketed fertilizer pellets are used for agricultural (excluding crops for human consumption) or horticulture.

$$ 75\ m^3 $$

Monthly solids totals appear in <u><strong>Appendix D Solids Handling.</strong></u>

Production for 2021:

• 16,964 m<sup>3</sup> of sludge was processed

$$ 16,964\ m^3 $$

• 504 super sacks filled (approximately 631 kg/sack)

• 342,171 kg of pellets produced

• 2,416.3 pellet production hours

Production for 2020:

• 17,216.1 m<sup>3</sup> of sludge was processed

$$ 17,216.1\ m^{3} $$

• 492 super sacks filled (approximately 631 kg/sack)

• 358,891.2 kg of pellets produced

• 2,469.2 pellet production hours

2.8 Combined Sewer Overflow Tank

2.8 Combined Sewer Overflow Tank

Excessive storm water/snow melt flows are handled by temporary storage in the Combined Sewer Overflow Tank (CSO). The capacity of the tank is approximately 4,000 m<sup>3</sup> or 4 million liters. As storm water/snowmelt flows subside, the captured wastewater is fed back into the main process flows for treatment. Flows exceeding the capacity of the CSO tanks will bypass secondary treatment (Aeration and Tertiary) via the bypass pipe and then blended with process flow which has received aeration, secondary clarification and filtration. This blended flow of bypass and process wastewater passes through UV treatment before discharge to the receiving water (Rideau River).

$$ 4,000\ m^{3} $$


3.0 Environmental Compliance Approval & Licensing

For the year 2021, the Smiths Falls WPCP operated under amended Environmental Compliance Approval (ECA) Number 5671-AE7HFT which was issued on January 11<sup>th</sup>, 2017. The facility has been designated as a Class IV facility under the Licensing of Sewage Works Operators Regulation, O. Reg. 129/04 made under the Ontario Water Resources Act.

The ECA establishes terms and conditions which the WPCP must operate under at all times.
These terms and conditions establish effluent objectives, effluent limits, operation and maintenance, monitoring and recording along with reporting requirements of the WPCP. Should these requirements not be met the facility is not complying with the ECA.

The ECA also establishes the Rated Capacity for the facility which is 14,700 m<sup>3</sup>/d. For 2021, the average daily flow was 7,761.19 m<sup>3</sup>. For the reporting period of 2021, the WPCP operated at an average of 52.80% of the rated capacity. Typically, the average flows are between 60% and 70%.

$$ 7,761.19\ m^3 $$

The Licensing of Sewage Works Operators Regulation, O. Reg. 129/04 requires the owner to ensure that everyone would works in the facility holds a license applicable to the type of facility. This regulation also requires the designation of an overall responsible operator (ORO) for the facility and that the ORO holds a license applicable to and of the same class as or higher than the class of the facility or one level below for no longer than six months out of a year. Both of these requirements are being met.

A copy of Environmental Compliance Approval number 5671-AE7HFT which the facility operated under in 2021 can be found in <u><strong><em>Appendix A.</em></strong></u>

4.0 Monitoring Data

4.0 Monitoring Data

The ECA lists effluent limits for Carbonaceous Biochemical Oxygen Demand (CBOD5), Total Suspended Solids (TSS), Total Phosphorus (TP), Total Ammonia Nitrogen (NH3), pH and E. coli. The limits are used to determine monthly compliance with the ECA and to determine if the process is functioning as per the ECA requirements.


4.1 Performance of Effluent Quality Assurance or Control Measures

The WPCP maintains a weekly sampling schedule of Raw Influent and Final Effluent as per the requirements listed in the monitoring and recording Condition of the ECA. Analyses are performed in-house or sent to an accredited laboratory as part of a quality assurance program, and as such, the results are utilized to identify any process changes required. All such analysis are included as part of the monitoring data in this report. Plant performance data is stored both in-house as well as on an online repository known as WaterTrax®.

Monitoring data and a comparison to effluent limits can be found in <u><strong>Appendix B.</strong></u>

4.2 Meeting Final Effluent Limits & Objectives

During this reporting period the treatment train produced an effluent that overall met all limits as indicated in the ECA.

Compliance was achieved with the Final <u><em>“Effluent Limits”</em></u> during the reporting period for monthly average concentrations and monthly average waste loadings for Carbonaceous Biochemical Oxygen Demand (CBOD5), Total Suspended Solids (TSS), Total Phosphorus (TP), Total Ammonia Nitrogen (NH3), pH and the monthly Geomean for E. coli.

Compliance was also achieved with the Final <u><em>“Objective Limits”</em></u> during the reporting period for monthly average concentrations for Carbonaceous Biochemical Oxygen Demand (CBOD5), Total Phosphorus (TP), Total Ammonia Nitrogen (NH3), pH and the monthly Geomean for E. coli. ECA Objectives are non-enforceable effluent quality results which wastewater plants are obligated to use best efforts to achieve on an on-going basis.

A summary and interpretation of all monitoring data and a comparison to the effluent limits in Condition 7 in the Environmental Compliance Approvals (ECA), including an overview of the success and adequacy of the Works can be found in <u><strong>Appendix B.</strong></u>


5.0 Performance of Secondary Treatment By-pass Events

In 2021, the WPCP experienced no secondary treatment by-passes, this is the first time there has been no by-passes since the construction of the combine sewer overflow tank in 2011. This this is quite an achievement.

All secondary treatment by-pass events are reported verbally to the MECP Spills Action Centre (SAC). Agencies notified via fax or email includes SAC, and the Leeds Grenville and Lanark District Health Unit. Samples of the by-pass events are collected and sent to our accredited laboratory when possible. Every effort is made to have each by-pass event sampled in accordance with the ECA, this could include driving samples to the laboratory or couriering them.

There can be no raw sewage by-passes to the environment at the WPCP. All wastewater entering the facility receives at a minimum, preliminary treatment, grit removal and primary treatment along with UV irradiation and blending with the secondary and tertiary effluent wastewater stream before discharge to the Rideau River.

The bypass summary was submitted to the Ministry on the following dates February 7<sup>th</sup>, May 10<sup>th</sup>, August 10<sup>th</sup> and November 8<sup>th</sup>.

$$ 7^{th} $$

$$ 10^{th} $$

$$ 10^{th} $$

$$ 8^{th} $$

The below table is a summary of the secondary treatment bypasses from 2016 to 2021

YEARNumber of Secondary Treatment BypassesTotal Duration (Hr)Total Volume (m3)
2016597.723,280.0
20177912.4317,655.0
201891,722.0597,430.0
20196121.927,114.0
20205105.942,639.7
202100.00.0

$$ (m^{3}) $$


6.0 Operational Problems & Corrective Actions

There were no operational problems during the reporting period that caused treatment plant issue with the ECA.

7.0 On Call

The operators are provided with their own Town issued mobile phone. These lines of communication, allow the operator to connect to the SCADA (Supervisory Control and Data Acquisition) system and immediately take measures to monitor or correct abnormal operational issues. Should an alarm fail to be answered or acknowledged, it will go through the programmed WIN-911 list which the Manager is a part of and can take the required action if needed.

8.0 Performance of all Maintenance

8.0 Performance of all Maintenance

During the reporting period, reactive maintenance, preventative maintenance, and predictive maintenance was performed as required and, on a routine basis or, as recommended by the equipment manufacturer manuals.

An electronic work order management system (MESH) is also being used to track preventative and corrective maintenance activities.

Below are some of the major maintenance highlights:

S Motor (M111): seized required replacement along with pulleys and belts

S Sizer (M1430): contractor install new hardware on vibrating sizer motors

S Sizer (M1430): bearings failed, replace lower motor

S Mixer (3040): mixer tripping out, gear box noisy, replace SEW drive with Nord gear drive from stock

S Belt press decanter: contractor installed new rollers and bearings as well as completed alignment

S Mixer (M920): failed, required complete replacement by contractor with new unit and anchors

S Mixer (M930): sludge tank 2 mixer broken, requires repairs. Housing sent to contractor for repairs, decided to replace with new unit and shaft

S Pump (M103): winding temp sensor not online possible bad connection or wire, pump sent to contractor for repair.

S Sizer (M1430): Replaced oversized and target screen, require new screens to be made up both had tears.


S Sludge lift pump: shaft broken, pump sent to contractor for repairs who is waiting on parts to complete the repair.

A summary of 2021 Maintenance Records can be found in <u><strong>Appendix C.</strong></u>

$$ c. $$

8.1 Centre St Pumping Station

8.1 Centre St Pumping Station

During the reporting period the following operating problems, issues and corrective actions were completed at the Centre St pumping station:

Operating problems, issues and corrective actions

S Communication issues correct by re-setting the router

o January 1<sup>st</sup>, April 8<sup>th</sup> & November 4th, 2021

$$ 8^{th} $$

S Power outage required pump station to run on portable generator

o March 14<sup>th</sup>

$$ 14^{th} $$

S Low pump output on pump #2, taken out of service

o October 8<sup>th</sup>

S Replaced pump #2, old pump sent away to be rebuilt

o October 21<sup>st</sup>

Maintenance or calibrations carried out on equipment

S Oct 21: Pump #2 replaced

S Dec 2: Flow meter was verified / calibrated

No complaints received during reporting period.

9.0 Performance of Verification and or Maintenance on Effluent

Monitoring Equipment

There are two Parshall Flumes in service at the WPCP. One measures Secondary Clarifier (SC) flow, and the other measures Final Effluent (FE) flow. Verifications were performed on the Final Effluent, Secondary Effluent Flow meter and the Secondary Bypass Flow meter in December 2021. There were also nine (9) flow meters that were verified in December 2021 as well.


10.0 Sludge Generation

10.0 Sludge Generation

Approximately, 16,964 m<sup>3</sup> of sludge was processed in 2021. Sludge generation is not anticipated to increase significantly during the next reporting period. The sludge generated is processed into pellets which are in turn sold to TerraPure Environmental to facilitate sales for farmers to spread on their fields as fertilizer. These pellets are regulated by the Canadian Food Inspection Agency (CFIA) under the Fertilizer Act. Exact locations of the farmers’ disposal sites (fields) are decided by the farmer.

Contingency

In the event that primary sludge must be hauled offsite, arrangements have been made with the Robert O. Picard Environmental Center (ROPEC) in Ottawa. As well, primary sludge and processed cake can be shipped to waste sites operated by TerraPure Environmental.

Only MECP approved and licensed haulers are used to transport the sludge or cake. Little to no change in sludge generation is anticipated over the next reporting period.

A summary of 2021 Sludge Solids Handling can be found in <u><strong>Appendix D.</strong></u>

11.0 Summary Complaints

11.0 Summary Complaints

There were no complaints received during the reporting period in 2021 regarding the WPCP.
Should a complaint be received immediate steps are taken to rectify the issue.

12.0 Ministry of Environment Conservation & Parks Communal Sewage Inspection Report

There was no Ministry of the Environment Conservation and Parks (MECP) inspection conducted during the inspection period.

13.0 Waste Received from Outside Smiths Falls

No septage was received at the Smiths Falls WPCP during the reporting period.

14.0 Municipal Utility Monitoring Program (MUMPs) Report

On a monthly basis a MUMPs compliance report is completed and submitted electronically to the MECP. This report contains the following information; monthly flows, secondary treatment by-pass flows (if an event occurred) and, Raw & Final effluent parameters. This report is to ensure the WPCP remains in compliance with the ECA. MUMPs reports from 2021 can be found in <u><strong>Appendix E.</strong></u>

15.0 Operator Licenses

15.0 Operator Licenses

Section 14 (1) of O. Reg. 129/04 requires that the owner of the facility ensures that every operator employed or performing operational duties in the facility holds a valid license. A list of operator licenses can be found in <u><strong>Appendix</strong></u> F.

16.0 Notice of Modifications (Limited Operational Flexibility)

There were two (2) notices of modification (limited operational flexibility) completed in 2021. One was for the installation and configuration of WIN911 software to handle all alarms, the other was supply and configuration to update the PLC equipment. The Notice of Modification to Sewage Works and report on further details can be found in <u><strong>Appendix G.</strong></u>

$$ G_{1} $$


APPENDIX A

Certificate of Approval Number 5671-AE7HFT Certificate of Approval Number 8-4041-93-006


Ontario

Ministry of the Environment and Climate Change Ministère de l’Environnement et de l’Action en matière de changement climatique

AMENDED ENVIRONMENTAL COMPLIANCE APPROVAL

NUMBER 5671-AE7HFT

Issue Date: January 11, 2017

The Corporation of the Separated Town of Smiths Falls

77 Beckwith St N

Post Office Box, No. 695

Smiths Falls, Ontario

K7A 4T6

Site Location: Smiths Falls Water Pollution Control Plant (WPCP) 180 Queen St Smiths Falls, County of Lanark

You have applied under section 20.2 of Part II.1 of the <u><em>Environmental Protection Act,</em></u> R.S.O. 1990, c. E. 19 (Environmental Protection Act) for approval of:

municipal sewage works for the transmission and treatment of sanitary sewage from the Separated Town of Smiths Falls and disposal of effluent to Rideau River via a Sewage Treatment Plant (Smiths Falls WPCP) having a Rated Capacity of 14,700 m /d, consisting of the following:<sup>3</sup>

Previous Works

Centre Street Sewage Pumping Station

one (1) 4.21 m x 1.5 m x 4.25 m SWD wetwell/drywell style sewage pumping station located at 57 Center Street, equipped with two (2) sewage pumps (one standby), each rated at 17.7 L/s at 9.86 m TDH and controlled by variable frequency drives;

flow meter and station bypass pumping chamber;

a 16 kW diesel generator set;

a 150 mm diameter forcemain along Centre Street, discharging to manhole #368 at Centre Street and Elmsley Street and therefrom to the main truck sewer discharging at the Smiths Falls WPCP;


Smiths Falls Water Pollution Control Plant

a conventional activated sludge process plant located at 180 Queen Street, having a Rated Capacity of 14,700 m /d, discharging effluent to Rideau River.<sup>3</sup>

Inlet Sewers

one (1) 900 mm and 1200 mm diameter gravity inlet sewer from the south side trunk sewer Rideau River underpass outlet to the raw sewage pumping station inlet chamber;

one (1) 900 mm diameter gravity sewer from the Highway 43 trunk sewer to the inlet sewer described above;

Raw Sewage Pumping Station

a raw sewage pumping station with an inlet chamber and two wet wells, equipped with three (3) (one standby) submersible pumps, each rated at 352 L/s at 15.3 m TDH, discharging into a channel leading to the Preliminary Treatment;

Wet Weather Flow Storage Tank

one (1) 4000 m tank to temporarily store wet weather flows that exceed the capacity of the<sup>3</sup> secondary treatment system;

two (2) tank discharge pumps (one standby) to return stored sewage back to the primary tank or aeration tank for treatment after the wet weather event, each pump rated at 44 L/s at 7.5 m TDH;

Preliminary Treatment

Screening

two (2) parallel screen channels, each with a Peak Flow Rate of 25,230 m /d and<sup>3</sup> equipped with an automatic self-cleaning screen with 25 mm (vertical) x 6 mm (horizontal) mesh, including a screw conveyor screenings de-watering press and screenings disposal bin;

Girt Removal

two (2) girt removal units, each with a Peak Flow Rate of 25,350 m /d with two (2) grit<sup>3</sup> pumps, each rated at 15.8 to 20.5 L/s at 11.4 to 15.5 m TDH including a grit de-watering unit and grit disposal bin;


Primary Sedimentation

two (2) 38.1 m x 10.06 m x 3.72 m SWD twin-pass primary clarifiers, each with a Peak Flow Rate of 25,230 m /d and equipped with sludge and scum removal mechanisms;<sup>3</sup>

two (2) primary sludge and scum pumps, each rated at 22.7 L/s at 34.75 m TDH;

Secondary Treatment

Biological Treatment

two (2) 39.6 m x 12.5 m x 4.6 m SWD complete mix aeration tanks, equipped with fine bubble aeration systems;

3 three (3) air blowers (two standby), rated at 64.3 m /min at 51.7 kPa;

Secondary Sedimentation

two (2) 46.2 m x 12.2 m x 3.6 m SWD twin-pass secondary clarifiers, equipped with sludge and scum mechanisms;

three (3) variable speed return activated sludge pumps (one standby), each rated at 37.8 to 86.5 L/s at 2.7 to 8.2 m TDH;

two (2) variable speed waste activated sludge pumps, each rated at 6.3 L/s at 7.5 m TDH;

Tertiary Treatment

two (2) 18.9 m x 5.0 m x 2.4 m single media gravity type tertiary filters, each with a Peak Flow Rate of 25,230 m /h, with automatic continuous backwash;<sup>3</sup>

Supplementary Treatment

Phosphorus Removal

two (2) 18.9 m<sup>3</sup> chemical storage tanks, equipped with four (4) metering pumps each rated at 19.5 to 215 L/h, with dosing points at the influent and the effluent channels of the secondary clarifier and in the flash mix tank;

one (1) flash mix tank being a 2.7 m long section of the flocculation tank inlet channel, equipped with a 2.2 kW mixer;

two (2) 6.45 m x 6.45 m x 5.1 m SWD flocculation tanks with overflow gates to the tertiary filter influent channel, each equipped with a 1.1 kW flocculator;

Disinfection

a 11 m x 1.75 m x 1.4 m deep UV disinfection system, equipped with an automatic liquid level controller on the outlet to the plant effluent channel, and a low pressure mercury vapour ultraviolet irradiation lamp system with 65% of the radiation output at the wave length of


253.7 nm and a nominal average intensity of radiation of 6150 µW/cm at 65% transmission,<sup>2</sup> consisting of three (3) in-series independently operated banks of removable lamp modules;

$$ 6150\ \mu W/cm^2 $$

Effluent Outfall

a 1,050 mm diameter outfall sewer extending approx. 145 m south from the end of the plant effluent channel to mid-stream Rideau River past the navigational channel (the river portion buried in the river bed), including a multi-port outfall structure on the outlet, and a valved emergency connection to the old outfall sewer;

Sludge Management

two (2) 75 m mixed sludge (primary and thickened waste activated) holding tanks, each<sup>3</sup> equipped with an mixer;

one (1) filter press sludge feed pump rated at a 2.7 L/s at 296 kPa, equipped with variable speed drive, together with a 3 hp motor sludge mercerator on the pump's suction line;

one (1) belt filter press rated at a sludge loading of 7.0 m /h at a solids concentration of 4%,<sup>3</sup> together with a polymer solution preparation and metering unit, an in-line mixer, and a 0.55 L/s capacity variable speed drive sludge cake transfer pump;

a sludge drying facility (the pelletizer) rated at a sludge loading rate of 1.71 m/h at a solids concentration of 25%, consisting of a twin shaft dryer feed mixer, a rotary drier, a cyclone type solids separator, a vibrating screen type sludge pellet classifier, two (2) final product cooling, and storage silos with a bagging facility;

Standby Power

one (1) 600 kW standby power diesel engine generator set with one (1) 900 litre capacity fuel tank located in the pelletizer building;

all other controls, electrical equipment, instrumentation, piping, pumps, valves and appurtenances essential for the proper operation of the aforementioned Sewage Works;

all in accordance with the submitted supporting documents listed in Schedule A.

For the purpose of this environmental compliance approval, the following definitions apply:

"Approval" means this entire document and any schedules attached to it;

"Annual Average Daily Flow" means the cumulative total sewage flow to the sewage works during a calendar year divided by the number of days during which sewage was flowing to the sewage works that year;

"BOD5" (also known as TBOD5) means five day biochemical oxygen demand measured in an unfiltered sample and includes carbonaceous and nitrogenous oxygen demand;

"Bypass" means diversion of sewage around one or more unit processes within the Sewage Treatment Plant with the diverted sewage flows being returned to the Sewage Treatment Plant treatment train upstream of the Final Effluent sampling location, and discharging to the environment through the Sewage Treatment Plant outfall;

"CBOD5" means five day carbonaceous (nitrification inhibited) biochemical oxygen demand measured in an unfiltered sample;

"Daily Concentration" means the concentration of a contaminant in the effluent discharged over any single day, as measured by a composite or grab sample, whichever is required;

"Director" means a person appointed by the Minister pursuant to section 5 of the EPA for the purposes of Part II.1 of the EPA;

"E. coli " refers to the thermally tolerant forms of Escherichia that can survive at 44.5 degrees Celsius;

"Emergency Situation" means a structural, mechanical or electrical failure that causes a temporary reduction in the capacity of the Sewage Treatment Plant or an unforeseen flow condition that may result in:

a. danger to the health or safety of any person; or,

b. injury or damage to any property, or serious risk of injury or damage to any property; or

c. treatment process biomass washout.

"EPA" means the <u><em>Environmental Protection Act,</em></u> R.S.O. 1990, c.E.19, as amended;

"Equivalent Equipment" means a substituted equipment or like-for-like equipment that meets the required quality and performance standards of a named equipment;

"Event" means an action or occurrence, at a given location within the Sewage Treatment Plant that causes a Bypass or Overflow. An Event ends when there is no recurrence of a Bypass or Overflow in the 12-hour period following the last Bypass or Overflow. Two Events are separated by at least 12 hours during which there has been no recurrence of a Bypass or Overflow. An Overflow and a Bypass are two separate reportable Events even when occurring concurrently;

"Final Effluent" means effluent discharged through the Final Effluent sampling location and via the Sewage Treatment Plant outfall to the environment;

"Geometric Mean Density" is the nth root of the product of multiplication of the results of n number of samples over the period specified;

"Limited Operational Flexibility” (LOF) means any modifications that the Owner is permitted to make to the Works under this Approval;

"Ministry" means the ministry of the government of Ontario responsible for the EPA and OWRA and includes all officials, employees or other persons acting on its behalf;

"Monthly Average Concentration" means the arithmetic mean of all Daily Concentrations of a contaminant in the effluent sampled or measured, or both, during a calendar month;

"Monthly Average Daily Flow" means the cumulative total sewage flow to the sewage works during a calendar month divided by the number of days during which sewage was flowing to the sewage works that month;

"Monthly Average Loading" means the value obtained by multiplying the Monthly Average Concentration of a contaminant by the Monthly Average Daily Flow over the same calendar month;

"Owner" means The Corporation of the Separated Town of Smiths Falls and its successors and assignees;

"OWRA" means the <u><em>Ontario Water Resources Act,</em></u> R.S.O. 1990, c. O.40, as amended;

"Peak Flow Rate" means the maximum rate of sewage flow for which the plant or process unit was designed;

"Overflow" means a discharge to the environment from the Works at a location other than the Sewage Treatment Plant effluent outfall or into the effluent outfall downstream of the Final Effluent sampling location;

"Previous Works" means those portions of the sewage works previously constructed and approved under an approval;

"Rated Capacity" means the Annual Average Daily Flow for which the Sewage Treatment Plant is approved to handle;

"Sewage Treatment Plant" means the entire sewage treatment and effluent discharge facility;

"Water Supervisor" means the Water Compliance Supervisor for the Safe Drinking Water Branch (SDWB) for the Kingston, Ottawa, and Cornwall office of the Ministry; and

"Works" means the sewage works described in the Owner's application, and this Approval, and includes Previous Works, and modifications made under Limited Operational Flexibility.

You are hereby notified that this environmental compliance approval is issued to you subject to the terms and conditions outlined below:

TERMS AND CONDITIONS

1. GENERAL PROVISIONS

(1) The Owner shall ensure that any person authorized to carry out work on or operate any aspect of the Works is notified of this Approval and the conditions herein and shall take all reasonable measures to ensure any such person complies with the same.

(2) Except as otherwise provided by these conditions, the Owner shall design, build, install, operate and maintain the Works in accordance with the description given in this Approval, and the application for approval of the Works.

(3) Where there is a conflict between a provision of any document in the schedule referred to in this Approval and the conditions of this Approval, the Conditions in this Approval shall take precedence, and where there is a conflict between the documents in the schedule, the document bearing the most recent date shall prevail.

(4) Where there is a conflict between the documents listed in the Schedule A, and the application, the application shall take precedence unless it is clear that the purpose of the document was to amend the application.

(5) The Conditions of this Approval are severable. If any Condition of this Approval, or the application of any requirement of this Approval to any circumstance, is held invalid or unenforceable, the application of such condition to other circumstances and the remainder of this Approval shall not be affected thereby.

2. CHANGE OF OWNER

(1) The Owner shall notify the Water Supervisor and the Director, in writing, of any of the following changes within thirty (30) days of the change occurring:

a. change of Owner;

b. change of address of the Owner;

c. change of partners where the Owner is or at any time becomes a partnership, and a copy of the most recent declaration filed under the <u><em>Business Names Act,</em></u> R.S.O. 1990, c.B17 shall be included in the notification to the Water Supervisor;

d. change of name of the corporation where the Owner is or at any time becomes a corporation, and a copy of the most current information filed under the <u><em>Corporations Information Act,</em></u> R.S.O. 1990, c. C39 shall be included in the notification to the Water Supervisor;

(2) In the event of any change in ownership of the Works, other than a change to a successor municipality, the Owner shall notify in writing the succeeding owner of the existence of this Approval, and a copy of such notice shall be forwarded to the Water Supervisor and the Director.

3. RECORD DRAWINGS

(1) A set of as-built drawings showing the Works "as constructed" shall be prepared or updated. These drawings shall be kept up to date through revisions undertaken from time to time and a copy shall be retained at the Works for the operational life of the Works.


4. BYPASSES

(1) Any Bypass is prohibited, except:

a. in an emergency situation when a structural, mechanical or electrical failure that causes a temporary reduction in the capacity of the Sewage Treatment Plant or in unexpected and/or unavoidable circumstance(s) that are likely to result in personal injury, loss of life, health hazard, basement flooding, severe property damage, equipment damage or treatment process upset;

b. where the Bypass is a direct and unavoidable result of a planned maintenance procedure or other circumstance(s), the Owner having notified the Water Supervisor at least fifteen (15) days prior to the occurrence of Bypass, including an assessment of the potential adverse effects on the environment and the anticipated duration of the Bypass and the mitigation measures, and the Water Supervisor has given written consent of the Bypass;

(2) For any Bypass Event, the Owner shall forthwith notify the Spills Action Centre (SAC), and the local Medical Officer of Health. This notice shall include, at a minimum, the following information for each Event:

a. the date(s), time(s) of the Bypass(es);

b. the treatment process(es) Bypassed and the status of the disinfection;

c. the reason(s) for the Bypass(es).

(3) After any Bypass Event, the Owner shall collect and record the following information:

a. the duration of the Bypass Event;

b. the measured or the estimated volume of Bypass(es) for each Event.

(4) The Owner shall use best efforts to collect a representative sample consisting of a minimum of two (2) grab samples of the Bypass and have it analysed for parameters outlined in Condition 7 using the protocol specified in Condition 9, one at the beginning of the Event and the second approximately near the end of the Event, to best reflect the effluent quality of such Bypass. For a specific situation when the facility is unmanned during the Event, a composite sample of the Final Effluent is accepted.

(5) The Owner shall submit a summary report of the Bypass Event(s) to the Water Supervisor on a quarterly basis, no later than each of the following dates for each calendar year: February 15, May 15, August 15, and November 15. The summary reports shall be in an electronic format, which shall contain, at a minimum, the types of information set out in Subsections (2), (3) and (4) for Bypass(es). The Water Supervisor may modify the reporting frequency at any time in writing.


5. OVERFLOWS

(1) Any Overflow is prohibited, except:

a. in an emergency situation when a structural, mechanical or electrical failure that causes a temporary reduction in the capacity of the Sewage Treatment Plant or in unexpected and/or unavoidable circumstance(s) that are likely to result in personal injury, loss of life, health hazard, basement flooding, severe property damage, equipment damage or treatment process upset;

b. where the Overflow is a direct and unavoidable result of a planned maintenance procedure or other circumstance(s), the Owner having notified the Water Supervisor at least fifteen (15) days prior to the occurrence of the Overflow, including an assessment of the potential adverse effects on the environment and the anticipated duration of the Overflow and any mitigation measures, and the Water Supervisor has given written consent of the Overflow.

(2) For any Overflow Event, the Owner shall forthwith notify the Spills Action Centre (SAC) and the local Medical Officer of Health. This notice shall include, at a minimum, the following information for each Event:

a. the date(s), time(s) of the Overflow(s);

b. the location(s) of the Overflow(s) and the receiver;

c. the reason(s) for the Overflow(s); and

a. the level of treatment the Overflow(s) has received and disinfection status of same.

(3) After any Overflow Event, the Owner shall collect and record the following information:

a. the duration of the Overflow Event;

b. the monitored or estimated volume of the Overflow(s); and

c. the impact of Overflow(s) on the receiver.

(4) For each Overflow Event, the Owner shall collect samples, representative of the Event, consisting of a minimum of two (2) grab samples of the Overflow, one at the beginning of the Event and one approximately near the end of the Event, and every 4 hours for the duration of the Event, and have them analyzed for effluent parameters outlined in Effluent Limits condition. For raw sewage and primary treatment system Overflow, BOD5 shall be monitored instead of CBOD5 and monitoring of E. coli is not required.

(5) The Owner shall submit a summary report of the Overflow Event(s) to the Water Supervisor on a quarterly basis, no later than each of the following dates for each calendar year: February 15, May 15, August 15, and November 15. The summary report shall be in an electronic format, which shall contain, at a minimum; the types of information set out in Subsections (2), (3) and (4) for Overflow(s). The Water Supervisor may modify the reporting frequency at any time in writing.

6. EFFLUENT OBJECTIVES

(1) The Owner shall use best efforts to design, construct and operate the Works with the objective that the concentrations of the materials named below as effluent parameters are not exceeded in the effluent from the Sewage Treatment Plant.

Table 1 - Effluent Objectives
Effluent ParameterConcentration Objective (milligrams per litre unless otherwise indicated)
CBOD510
Total Suspended Solids5
Total Phosphorus0.25
Total Ammonia Nitrogen2.0 (Jun 1 to Aug 31) 12.0 (Sept 1 to May 31)

(2) The Owner shall use best efforts to:

a. maintain the pH of the effluent from the Works within the range of 6.5 - 8.5, inclusive, at all times;

b. operate the works within the Rated Capacity of the Works;

c. ensure that the effluent from the Works is essentially free of floating and settleable solids and does not contain oil or any other substance in amounts sufficient to create a visible film or sheen or foam or discolouration on the receiving waters.

d. ensure that the effluent is continuously disinfected during the disinfection period so that the monthly Geometric Mean Density of E. coli does not exceed 150 organisms per 100 millilitres of effluent discharged from the Sewage Treatment Plant.


7. EFFLUENT LIMITS

(1) The Owner shall operate and maintain the Works such that the concentrations of the materials named below as effluent parameters are not exceeded in the effluent from the Sewage Treatment Plant.

Table 2 - Final Effluent Limits
Effluent ParameterAverage Concentration (milligrams per litre unless otherwise indicated)Average Waste Loading (kilograms per day unless otherwise indicated)
Column 1Column 2Column 3
CBOD515220.5
Total Suspended Solids15220.5
Total Phosphorus0.34.4
Total Ammonia Nitrogen2.6 (Jun 1 to Aug 31)14.0 (Sept 1 to May 31)38.0 (Jun 1 to Aug 31)206.0 (Sept 1 to May 31)

(2) For the purposes of determining compliance with and enforcing subsection (1):

a. The Monthly Average Concentration of a parameter named in Column 1 of subsection (1) shall not exceed the corresponding maximum concentration set out in Column 2 of subsection (1).

b. The Monthly Average Loading of a parameter named in Column 1 of subsection (1) shall not exceed the corresponding maximum waste loading set out in Column 3 of subsection (1).

(3) The Owner shall operate and maintain the Works such that the pH of the effluent from the Sewage Treatment Plant is maintained within the range of 6.0 - 9.5, inclusive, at all times.

(4) Notwithstanding subsection (1), the Owner shall operate and maintain the Works such that the effluent is continuously disinfected so that the monthly Geometric Mean Density of E. Coli does not exceed 200 organisms per 100 millilitres of effluent discharged from the Works.

8. OPERATION AND MAINTENANCE

(1) The Owner shall exercise due diligence in ensuring that, at all times, the Works and the related equipment and appurtenances used to achieve compliance with this Approval are properly operated and maintained. Proper operation and maintenance shall include effective performance, adequate funding, adequate operator staffing and training, including training in all procedures and other requirements of this Approval and the Act and regulations, adequate laboratory facilities, process controls and alarms and the use of process chemicals and other substances used in the Works.

(2) The Owner shall prepare an operations manual, that includes, but not necessarily limited to, the following information:


a. operating procedures for routine operation of the Works;

b. inspection programs, including frequency of inspection, for the Works and the methods or tests employed to detect when maintenance is necessary;

c. repair and maintenance programs, including the frequency of repair and maintenance for the Works;

d. procedures for the inspection and calibration of monitoring equipment;

e. a spill prevention control and countermeasures plan, consisting of contingency plans and procedures for dealing with equipment breakdowns, potential spills and any other abnormal situations, including notification of the Water Supervisor; and

f. procedures for receiving, responding and recording public complaints, including recording any followup actions taken.

(3) The Owner shall maintain the operations manual current and retain a copy at the location of the Works for the operational life of the Works.Upon request, the Owner shall make the manual available to Ministry staff.

(4) The Owner shall provide for the overall operation of the Works with an operator who holds a licence that is applicable to that type of facility and that is of the same class as or higher than the class of the facility in accordance with Ontario Regulation 129/04.

9. MONITORING AND RECORDING

The Owner shall, upon commencement of operation of the Works, carry out the following monitoring program:

(1) All samples and measurements taken for the purposes of this Approval are to be taken at a time and in a location characteristic of the quality and quantity of the effluent stream over the time period being monitored.

(2) For the purposes of this condition, the following definitions apply:

a. Weekly means once each week;


(3) Samples shall be collected at the following sampling points, at the frequency specified, by means of the specified sample type and analyzed for each parameter listed and all results recorded:

Table 3 - Influent Monitoring
ParametersSample TypeFrequency
BOD5CompositeWeekly
Total Suspended SolidsCompositeWeekly
Total PhosphorusCompositeWeekly
Total Kjeldahl NitrogenCompositeWeekly
Table 4 - Final Effluent Monitoring
ParametersSample TypeFrequency
CBOD5CompositeWeekly
Total Suspended SolidsCompositeWeekly
Total PhosphorusCompositeWeekly
Total Ammonia NitrogenCompositeWeekly
E. coliGrabWeekly
pHGrabWeekly
TemperatureGrabWeekly
Unionized AmmoniaCalculatedWeekly

(4) The methods and protocols for sampling, analysis and recording shall conform, in order of precedence, to the methods and protocols specified in the following:

a. the Ministry's Procedure F-10-1, “Procedures for Sampling and Analysis Requirements for Municipal and Private Sewage Treatment Works (Liquid Waste Streams Only), as amended from time to time by more recently published editions;

b. the Ministry's publication "Protocol for the Sampling and Analysis of Industrial/Municipal Wastewater" (January 1999), ISBN 0-7778-1880-9, as amended from time to time by more recently published editions;

c. the publication "Standard Methods for the Examination of Water and Wastewater" (21st edition), as amended from time to time by more recently published editions;

(5) The temperature and pH of the effluent from the Works shall be determined in the field at the time of sampling for Total Ammonia Nitrogen. The concentration of un-ionized ammonia shall be calculated using the total ammonia concentration, pH and temperature using the methodology stipulated in "Ontario's Provincial Water Quality Objectives" dated July 1994, as amended, for ammonia (un-ionized).

(6) The Owner shall install and maintain (a) continuous flow measuring device(s), to measure the flowrate of the influent to the Sewage Treatment Plant with an accuracy to within plus or minus 15 per cent (+/- 15%) of the actual flowrate for the entire design range of the flow measuring device, and record the flowrate at a daily frequency.

(7) The Owner shall retain for a minimum of five (5) years from the date of their creation, all records and information related to or resulting from the monitoring activities required by this Approval.

10. LIMITED OPERATIONAL FLEXIBILITY(MODIFICATIONS TO THE WORKS)

(1) The Owner may make modifications to the Works in accordance with the Terms and Conditions of this Approval and subject to the Ministry’s “Limited Operational Flexibility Criteria for Modifications to Sewage Works ”, included under Schedule B of this Approval, as amended.

(2) Sewage works proposed under Limited Operational Flexibility shall adhere to the design guidelines contained within the Ministry’s publication “Design Guidelines for Sewage Works 2008”, as amended.

(3) The Owner shall ensure at all times, that the Works, related equipment and appurtenances which are installed or used to achieve compliance are operated in accordance with all Terms and Conditions of this Approval.

(4) For greater certainty, the following are not permitted as part of Limited Operational Flexibility:

a. Modifications to the Works that result in an increase of the approved Rated Capacity of the Works;

b. Modifications to the Works that may adversely affect the approved effluent quality criteria or the location of the discharge/outfall;

c. Modifications to the treatment process technology of the Works, or modifications that involve construction of new reactors (tanks) or alter the treatment train process design;

d. Modifications to the Works approved under s.9 of the EPA, and

e. Modifications to the Works pursuant to an order issued by the Ministry.

(5) Implementation of Limited Operational Flexibility is not intended to be used for piecemeal measures that result in major alterations or expansions.

(6) If the implementation of Limited Operational Flexibility requires changes to be made to the Emergency Response, Spill Reporting and Contingency Plan, the Owner shall, as deemed necessary in consultation with the Water Supervisor, provide a revised copy of this plan to the local fire services authority prior to implementing Limited Operational Flexibility.

(7) For greater certainty, any modification made under the Limited Operational Flexibility may only be carried out after other legal obligations have been complied with, including those arising from the Environmental Protection Act, Niagara Escarpment Planning and Development Act, Oak Ridges Moraine Conservation Act, Lake Simcoe Protection Act and Greenbelt Act.

(8) Prior to implementing Limited Operational Flexibility, the Owner shall complete a Notice of Modifications describing any proposed modifications to the Works and submit it to the Water Supervisor.

11. REPORTING

(1) The Owner shall report to the Water Supervisor orally as soon as possible any non-compliance with the effluent criteria, and in writing within seven (7) days of non-compliance.

(2) In addition to the obligations under Part X of the Environmental Protection Act, the Owner shall, within ten (10) working days of the occurrence of any reportable spill as defined in Ontario Regulation 675/98, bypass or loss of any product, by-product, intermediate product, oil, solvent, waste material or any other polluting substance into the environment, submit a full written report of the occurrence to the Water Supervisor describing the cause and discovery of the spill or loss, clean-up and recovery measures taken, preventative measures to be taken and schedule of implementation.

(3) The Owner shall, upon request, make all manuals, plans, records, data, procedures and supporting documentation available to Ministry staff.

(4) The Owner shall prepare and submit a performance report to the Water Supervisor on an annual basis, by March 31 of the year following the end of the period being reported upon. The first such report shall cover the first annual period following the commencement of operation of the Works and subsequent reports shall be submitted to cover successive annual periods following thereafter. The reports shall contain, but shall not be limited to, the following information:

a. a summary and interpretation of all monitoring data and a comparison to the effluent limits outlined in Condition 7, including an overview of the success and adequacy of the Works;

b. a description of any operating problems encountered and corrective actions taken;

c. a summary of all maintenance carried out on any major structure, equipment, apparatus, mechanism or thing forming part of the Works;

d. a summary of any effluent quality assurance or control measures undertaken in the reporting period;

e. a summary of the calibration and maintenance carried out on all effluent monitoring equipment; and

f. a description of efforts made and results achieved in meeting the Effluent Objectives of


Condition 6.

g. a tabulation of the volume of sludge generated in the reporting period, an outline of anticipated volumes to be generated in the next reporting period and a summary of the locations to where the sludge was disposed;

h. a summary of any complaints received during the reporting period and any steps taken to address the complaints;

i. a summary of all By-pass, spill or abnormal discharge events;

j. a copy of all Notice of Modifications submitted to the Water Supervisor as a result of Schedule B, Section 1, with a status report on the implementation of each modification;

k. a report summarizing all modifications completed as a result of Schedule B, Section 3; and

l. any other information the Water Supervisor requires from time to time.

(5) The Owner shall, within thirty (30) calendar days of issuance of this Approval, submit a Municipal and Local Services Board Wastewater System Profile Information Form, and shall resubmit the updated document every time a notification is provided to the Water Supervisor in compliance with requirements of change of ownership under this Approval.

The reasons for the imposition of these terms and conditions are as follows:

  1. Condition 1 is imposed to ensure that the Works are built and operated in the manner in which they were described for review and upon which approval was granted. This condition is also included to emphasize the precedence of Conditions in the Approval and the practice that the Approval is based on the most current document, if several conflicting documents are submitted for review. The condition also advises the Owners their responsibility to notify any person they authorized to carry out work pursuant to this Approval the existence of this Approval.

  2. Condition 2 is included to ensure that the Ministry records are kept accurate and current with respect to the approved works and to ensure that subsequent owners of the Works are made aware of the Approval and continue to operate the Works in compliance with it.

  3. Condition 3 is included to ensure that record drawings of the Works “as constructed” are maintained for future references.

  4. Condition 4 is included to indicate that By-pass of untreated or partially treated sewage to the receiving watercourse is prohibited, save in certain limited circumstances where the failure to By-pass could result in greater injury to the public interest than the Bypass itself where a By-pass will not violate the approved effluent requirements, or where the By-pass can be limited or otherwise mitigated by handling it in accordance with an approved contingency plan. The notification and documentation requirements allow the Ministry to take action in an informed manner and will ensure the Owner is aware of the extent and frequency of By-pass events.

  5. Condition 5 is included to indicate that Overflows of untreated or partially treated sewage to the receiving watercourse is prohibited, save in certain limited circumstances where the failure to Overflow could result in greater injury to the public interest than the Overflow itself or where the Overflow can be limited or otherwise mitigated by handling it in accordance with an approved contingency plan. The notification and documentation requirements allow the Ministry to take action in an informed manner and will ensure the Owner is aware of the extent and frequency of Overflow events.

  6. Condition 6 is imposed to establish non-enforceable effluent quality objectives which the Owner is obligated to use best efforts to strive towards on an ongoing basis. These objectives are to be used as a mechanism to trigger corrective action proactively and voluntarily before environmental impairment occurs and before the compliance limits of Condition 7 are exceeded.

  7. Condition 7 is imposed to ensure that the effluent discharged from the Works to the environment meets the Ministry's effluent quality requirements thus minimizing environmental impact on the receiver and to protect water quality, fish and other aquatic life in the receiving water body.

  8. Condition 8 is included to require that the Works be properly operated, maintained, funded, staffed and equipped such that the environment is protected and deterioration, loss, injury or damage to any person or property is prevented. As well, the inclusion of a comprehensive operations manual governing all significant areas of operation, maintenance and repair is prepared, implemented and kept up-to-date by the Owner and made available to the Ministry. Such a manual is an integral part of the operation of the Works. Its compilation and use should assist the Owner in staff training, in proper plant operation and in identifying and planning for contingencies during possible abnormal conditions. The manual will also act as a benchmark for Ministry staff when reviewing the Owner's operation of the Works.

  9. Condition 9 is included to enable the Owner to evaluate and demonstrate the performance of the Works, on a continual basis, so that the Works are properly operated and maintained at a level which is consistent with the design objectives and effluent limits specified in the Approval and that the Works does not cause any impairment to the environment.

  10. Condition 10 is included to provide a performance record for future references, to ensure that the Ministry is made aware of problems as they arise, and to provide a compliance record for all the terms and conditions outlined in this Approval, so that the Ministry can work with the Owner in resolving any problems in a timely manner.

  11. Condition 11 is included to ensure that the Works are operated in accordance with the application and supporting documentation submitted by the Owner, and not in a manner which the Director has not been asked to consider. These Conditions are also included to ensure that a Professional Engineer has reviewed the proposed modifications and attests that the modifications are in line with that of Limited Operational Flexibility, and provide assurance that the proposed modifications comply with the Ministry's requirements stipulated in the Terms and Conditions of this Approval, MOE policies, guidelines, and industry engineering standards and best management practices.


Schedule A

  1. All previous application and supporting documentation including the environmental study report, pre-design report, and plans and specifications prepared by Gore & Storrie Limited, and Thornburn Penny Limited;

  2. <u>Application for Approval of Municipal and Private Sewage Works</u> submitted by Tony Guerrera of The Greer Galloway Group Inc received May 28, 2010, including Town of Smiths Falls Pollution Prevention and Control Class Environmental Assessment Project File Report prepared by AECOM, Centre Street Sewage Pumping Station Design Report and final engineering plans for the CSO Tank and Centre Pumping Station Upgrade prepared by Greer Galloway Group.

  3. <u>Application for Approval of Municipal and Private Sewage Works</u>, submitted by M.G. Christie of XIE (environmental) received on August 4, 2016, including an application and accompanying transmittal form for the Request for Limited Operational Flexibility;


<u><strong>hedule B</strong></u>

Limited Operational Flexibility Criteria for Modifications to Municipal Sewage Works

  1. The modifications to sewage works approved under an Environmental Compliance Approval (Approval) that are permitted under the Limited Operational Flexibility (LOF), are outlined below and are subject to the LOF conditions in the Approval, and require the submission of the Notice of Modifications. If there is a conflict between the sewage works listed below and the Terms and Conditions in the Approval, the Terms and Conditions in the Approval shall take precedence.

1.1 Sewage Pumping Stations

a. Alter pumping capacity by adding or replacing equipment where new equipment is located within an existing sewage treatment plant site or an existing sewage pumping station site, provided that the modifications do not result in an increase of the sewage treatment plant Rated Capacity and the existing flow process and/or treatment train are maintained, as applicable.

b. Forcemain relining and replacement with similar pipe size where the nominal diameter is not greater than 1,200 mm.

1.2 Sewage Treatment Process

a. Installing additional chemical dosage equipment including replacing with alternative chemicals for pH adjustment or coagulants (non-toxic polymers) provided that there are no modifications of treatment processes or other modifications that may alter the intent of operations and may have negative impacts on the effluent quantity and quality.

b. Expanding the buffer zone between a sanitary sewage lagoon facility or land treatment area and adjacent uses provided that the buffer zone is entirely on the proponent’s land.

c. Optimizing existing sanitary sewage lagoons with the purpose to increase efficiency of treatment operations provided that existing sewage treatment plant rated capacity is not exceeded and where no land acquisition is required.

d. Optimizing existing sewage treatment plant equipment with the purpose to increase the efficiency of the existing treatment operations, provided that there are no modifications to the works that result in an increase of the approved Rated Capacity, and may have adverse effects to the effluent quality or location of the discharge.

e. Replacement, refurbishment of previously approved equipment in whole or in part with Equivalent Equipment, like-for-like of different make and model, provided that the firm c apacity, reliability, performance standard, level of quality and redundancy of the group of equipment is kept the same or exceeded. For clarity purposes, the following equipment can be considered under this provision: pumps, screens, grit separators, blowers, aeration equipment, sludge thickeners, dewatering equipment, UV systems, chlorine contact equipment, bio-disks, and sludge digester systems.

1.3 Sewage Treatment Plant Outfall

a. Replacement of discharge pipe with similar pipe size or diffusers provided that the outfall location is not changed.

1.4 Sanitary Sewers

a. Pipe relining and replacement with similar pipe size within the Sewage Treatment Plant site, where the nominal diameter is not greater than 1,200 mm.

1.5 Pilot Systems

a. Installation of pilot systems for new or existing technologies provided that:

i. any effluent from the pilot system is discharged to the inlet of the sewage treatment plant or hauled off-site for proper disposal,

ii. any effluent from the pilot system discharged to the inlet of the sewage treatment plant or sewage conveyance system does not significantly alter the composition/concentration of the influent sewage to be treated in the downstream process; and that it does not add any inhibiting substances to the downstream process, and

iii. the pilot system’s duration does not exceed a maximum of two years; and a report with results is submitted to the Director and Water Supervisor three months after completion of the pilot project.

  1. Sewage works that are exempt from section 53 of the OWRA by O. Reg. 525/98 continue to be exempt and are not required to follow the notification process under this Limited Operational Flexibility.

  2. Normal or emergency operational modifications, such as repairs, reconstructions, or other improvements that are part of maintenance activities, including cleaning, renovations to existing approved sewage works equipment, provided that the modification is made with Equivalent Equipment, are considered pre-approved.

  3. The modifications noted in section (3) above are not required to follow the notification protocols under Limited Operational Flexibility, provided that the number of pieces and description of the equipment as described in the Approval does not change.


RETAIN COPY OF COMPLETED FORM AS PART OF THE ECA AND SEND A COPY TO THE WATER SUPERVISOR (FOR MUNICIPAL) OR DISTRICT MANAGER (FOR NON-MUNICIPAL SYSTEMS)

Part 1 – Environmental Compliance Approval (ECA) with Limited Operational Flexibility (Insert the ECA's owner, number and issuance date and notice number, which should start with "01" and consecutive numbers thereafter)
ECA NumberIssuance Date (mm/dd/yy)Notice number (if applicable)
ECA OwnerMunicipality

Part 2 Description of the documentation as part of the Limited Operation Flexibility

(Attach a detailed description of the sewage works)

Description shall include:

  1. A detail description of the modifications and/or operations to the sewage works (e.g. sewage work component, location, size, equipment type/model, material, process name, etc.)

  2. Confirmation that the anticipated environmental effects are negligible.

  3. List of updated versions of, or amendments to, all relevant technical documents that are affected by the modifications as applicable, i.e. submission of documentation is not required, but the listing of updated documents is (design brief, drawings, emergency plan, etc.)

Part 3 – Declaration by Professional Engineer
I hereby declare that I have verified the scope and technical aspects of this modification and confirm that the design:1. Has been prepared or reviewed by a Professional Engineer who is licensed to practice in the Province of Ontario;2. Has been designed in accordance with the Limited Operational Flexibility as described in the ECA;3. Has been designed consistent with Ministry's Design Guidelines, adhering to engineering standards, industry's best management practices, and demonstrating ongoing compliance with s.53 of the Ontario Water Resources Act; and other appropriate regulations.I hereby declare that to the best of my knowledge, information and belief the information contained in this form is complete and accurate
Name (Print)PEO License Number
SignatureDate (mm/dd/yy)
Name of Employer
Part 4 – Declaration by Owner
I hereby declare that:1. I am authorized by the Owner to complete this Declaration;2. The Owner consents to the modification; and3. This modifications to the sewage works are proposed in accordance with the Limited Operational Flexibility as described in the ECA.4. The Owner has fulfilled all applicable requirements of the Environmental Assessment Act.I hereby declare that to the best of my knowledge, information and belief the information contained in this form is complete and accurate
Name of Owner Representative (Print)Owner representative's title (Print)
Owner Representative's SignatureDate (mm/dd/yy)

EAB Form December 2, 2013


Upon issuance of the environmental compliance approval, I hereby revoke Approval No(s). 5076-86NKAG issued on July 12, 2010.

In accordance with Section 139 of the Environmental Protection Act, you may by written Notice served upon me and the Environmental Review Tribunal within 15 days after receipt of this Notice, require a hearing by the Tribunal. Section 142 of the Environmental Protection Act provides that the Notice requiring the hearing shall state:

  1. The portions of the environmental compliance approval or each term or condition in the environmental compliance approval in respect of which the hearing is required, and;

  2. The grounds on which you intend to rely at the hearing in relation to each portion appealed.

Pursuant to subsection 139(3) of the Environmental Protection Act, a hearing may not be required with respect to any terms and conditions in this environmental compliance approval, if the terms and conditions are substantially the same as those contained in an approval that is amended or revoked by this environmental compliance approval.

The Notice should also include:

  1. The name of the appellant;

  2. The address of the appellant;

  3. The environmental compliance approval number;

  4. The date of the environmental compliance approval;

  5. The name of the Director, and;

  6. The municipality or municipalities within which the project is to be engaged in.

And the Notice should be signed and dated by the appellant.

This Notice must be served upon:

The Director appointed for the purposes of Part II.1 of

The Secretary* Environmental Review Tribunal 655 Bay Street, Suite 1500 Toronto, Ontario M5G 1E5AND

135 St. Clair Avenue West, 1st Floor

*** Further information on the Environmental Review Tribunal’s requirements for an appeal can be obtained directly from the**
Tribunal at: Tel: (416) 212-6349, Fax: (416) 326-5370 or www.ert.gov.on.ca


The above noted activity is approved under s.20.3 of Part II.1 of the Environmental Protection Act.

DATED AT TORONTO this 11th day of January, 2017

RY/

c: DWMD Supervisor, MOECC Ottawa

Ted Joynt, Town of Smith Falls

Fariha Pannu, P.Eng.

Director

appointed for the purposes of Part II.1 of the

Environmental Protection Act


To the Applicant:

Town of Smiths Falls 191 Beckwith Street, Box 695 Smiths Falls, Ontario K7A 4T6

Located at:

Smiths Falls Waste Water Treatment Facility, Highway 43 and Herehey Road, Smiths Falls, Ontario.

The Applicant has applied in accordance with Section 9 of the Environmental Protection Act for approval of:

a waste water treatment facility with the following associated exhaust systems:

  • one (1) exhaust system serving the screen channels, screens, screening conveyors and screening bins, equipped with one (1) carbon adsorption unit, having 143 kilograms of activated carbon, exhausting into the atmosphere at a volumetric flowrate of 140 litres per second, through a louvre having a cross sectional area of 0.16 square metre, located at 7.5 metres above grade,

  • one (1) standby diesel generator, having a continuous rating of 600 kilowatts, fuelled by No. 2 diesel oil at a maximum rate of 145 litres per hour. The combustion products are discharged into the atmosphere through a stack having an exit diameter of 0.2 metre, extending 1.0 metre above the roof and 13.0 metres above grade. The diesel generator is equipped with noise control measures as specified in the "Environmental Noise Impact Study", dated November 27, 1992 and prepared by Barman Swallow Associates.

  • one (1) sludge pelletizer unit, equipped with:

    • one (1) natural gas fired burner having a maximum heat input of 3,838,045 kilojoules per hour;

    • one (1) baghouse dust collector serving the drying circuit, having a filtering velocity of 2.0 centimetres per second, equipped with Ryton/Rastex-PTFE filter bags and air pulse cleaning devices;

    • one (1) baghouse dust collector serving the cooling circuit, having a filtering velocity of 2.0 centimetres per second, equipped with Dralon T filter bags and air pulse cleaning devices;

The exhaust gases are discharged into the atmosphere at a volumetric flowrate of 1.6 normal cubic metres per second, through a stack having an exit diameter of 0.3 metre, extending 13.0 metres above grade; and,


Ministr Enviro and Er

of ment ergy

Ontario

CERTIFICATE OF APPROVAL

Ministère l'Environ et de l'E

de nement energie

NUMBER 8-4041-93-006

  • twenty six (26) exhaust fans to follows:

provide general ventilation. They are as

LOCATIONVENT NUMBERABOVE ROOF (metre)HEIGHT ABOVE GRADE (metre)VOLUMETRIC FLOWRATE (normal cubic metre per second)
Raw Sludge Pump StationEF10.41.50.34
Raw Sludge Pump StationEF20.41.51.30
Screen and Degrit Building Screen RoomEF30.46.90.67
Pump RoomEF40.46.92.80
Pump RoomEF50.46.92.80
BasementEF60.46.90.64
Grit Pump RoomEF70.41.50.30
Blower Building Blower RoomEF80.41.71.15
Blower Building Blower RoomEF90.41.78.00
MCC RoomEF100.44.62.33
MCC RoomEF11-3.00.09
Filter RoomEF120.44.61.57
Filter RoomEF130.44.61.57
Administration Building Mens Locker RoomEF140.45.90.35
Administration Building Mens Locker RoomEF150.45.90.35
Administration Building Mens Locker RoomEF160.45.90.35
Main ExhaustEF170.45.90.35
Main ExhaustEF180.45.90.35
Ladies Locker RoomEF190.45.90.35
Ladies Locker RoomEF200.45.90.35
Janitorial RoomEF210.45.90.35
LaboratoryEF220.45.90.35
Pelletizer Building Maintenance RoomEF23-4.00.22
WashroomEF240.410.90.022
PellitizerEF25-8.05.18
PellitizerEF26-8.02.59

all in accordance with the application for a Ce dated April 8,1993,signed by C. Kowalewski and prepared and submitted by Thornburn Penny.

tificate of Approval (Air) other supporting information


The Applicant is hereby notified that this approval is issued subject to the following terms and conditions outlined below:

TERMS AND CONDITIONS

DEFINITIONS

  1. For the purpose of this Certificate of Approval:

a. "Act" means the Environmental Protection Act;

b. "Certificate" means this Certificate of Approval, issued in accordance with Section 9 of the Environmental Protection Act;

c. "Company" means Town of Smiths Falls;

d.. "Burner" means the natural gas fired burner serving the sludge drying and pelletizing unit described in this Certificate;

e. "Diesel Generator" means the diesel generator set described in this Certificate;

f. "Director" means any Ministry employee appointed by the Minister pursuant to Section 5 of the Act;

g. "District Officer" means the District Officer, Ottawa District Office, Southeastern Region of the Ministry;

h. "Equipment" means the carbon adsorption unit, the baghouse dust collectors and the burner described in the Company's application, this Certificate and in the supporting documentation referred to herein, to the extent approved by this Certificate;

i. "Ministry" means the Ontario Ministry of Environment and Energy;

j. "Point of Impingement" means any point in the natural environment. The point of impingement for the purposes of verifying compliance with the Act shall be chosen as the point at which the highest concentration is expected to occur, when that concentration is calculated in accordance with the Appendix to Regulation 346 written under the Act, or any other method accepted by the Director;

k. "Pre-test Information" means the information outlined in Section 1.1. of the Source Testing Code;

l. "Source Testing Code" means the Source Testing Code, Version 2, Report No. ARB-66-80, dated November 1980, prepared by the Ministry, as amended;

m. "Source Testing" means sampling and testing to measure emissions resulting from operating the equipment under conditions which yield the worst case emissions within the approved operating range of the equipment.


n. "Supervisor" means the Supervisor, Source Assessment and Technology Unit, or any other person who represents and carries out the duties of the Supervisor, Source Assessment and Technology Unit, as those duties relate to the conditions of this Certificate;

o. "Test Contaminants" means total hydrocarbon, total reduced sulphur and total suspended particulate.

MAINTENANCE

  1. The Company, shall ensure that the Equipment is properly operated and maintained at all times. The Company shall, as a minimum:

a. prepare not later than three (3) months after the commencement of operation of the Equipment and update, as necessary, a manual outlining the operating procedures and a maintenance program for the Equipment;

b. implement the recommendations of the operating and maintenance manual; and

c. retain, for a minimum of two (2) years from the date of their creation, all records on the maintenance, repair and inspection of the Equipment.

SOURCE TESTING

  1. The Company shall monitor the emissions and operation of the Burner as follows:

a. The Company shall perform Source Testing, to determine the rate of emission of the Test Contaminants from the Burner.

b. The Company shall submit, not later than three (3) months after the commencement of operation of the Equipment, to the Supervisor a test protocol, including the Pre-Test Information for the Source Testing required by the Source Testing Code. The Company shall finalize the test protocol in consultation with the Supervisor.

c. The Company shall not commence the Source Testing until the Supervisor has accepted the test protocol.

d. The Company shall complete the Source Testing not later than three (3) months after the Supervisor has accepted the test protocol.

e. The Company shall notify the District Officer and the Supervisor in writing of the location, date and time of any impending Source Testing required by this Certificate, at least fifteen (15) days prior to the Source Testing.


f. The Company shall submit a report on the Source Testing to the District Officer and the Supervisor not later than two (2) months after completing the Source Testing. The report shall be in the format described in the Source Testing Code, and shall also include, but not be limited to:

i. an executive summary; ii. records of operating conditions, iii. the results of dispersion calculations in accordance with Regulation 346 indicating the maximum concentration of the Test contaminants at the Point of Impingement.

g. The Director may not accept the results of the Source Testing if: i. the Source Testing Code or the requirements of the Supervisor were not followed; or ii. the Company did not notify the District Officer and the Supervisor of the Source Testing; or iii. the Company failed to provide a complete report on the Source Testing.

h. If the Director does not accept the results of the Source Testing, the Director may require re-testing.

  1. The Company shall ensure that the noise emissions from the Diesel Generator comply with the limits determined in accordance with Publication NPC-105 of the Model Municipal Noise Control By-Law, Final Report, August 1978, as amended.

  2. The Company shall restrict the periodic testing of the Diesel Generator to the daytime period of 7 a.m. to 5 p.m.

The reasons for the imposition of these terms and conditions are as follows:

  1. Condition No. 1 is included to define the special terms that are used throughout the Certificate.

  2. Condition No. 2 is included on the Certificate to emphasize that the Equipment must be maintained and operated according to a procedure that will result in compliance with the Environmental Protection Act, the regulations and this Certificate.

In addition, the Company is required to keep records to assist the Director, Section 9 of the Environmental Protection Act, in determining whether or not the Equipment is being inspected and maintained as required by the Environmental Protection Act, the Regulations and this Certificate.


Ministr Enviro and Er

y of nment ergy

Ministère de l'Environnement et de l'Energie

NUMBER 8-4041-93-006 Page 6 of 6

  1. Condition No. 3 is included to require the Company to gather accurate information so that the environmental impact and subsequent compliances with the Act, the regulations and this Certificate can be verified.

  2. Condition No. 4 is included to provide the requirement considered necessary to prevent an a from the operation of the Diesel Generator.

minimum performance verse effect resulting

  1. Condition No. 5 is included to ensure that the proposed operation of the Diesel Generator is not extended beyond day-time hours. Operation outside these hours, when ambient sound levels are significantly lower, may result in non-compliance with the established sound level limits.

The Applicant may by written notice served upon me and the Environmental Appeal Board within 15 days after receipt of this Notice, require a hearing by the Board. Section 142 of the Environmental Protection Act, R.S.O. 1990, Chapter E.19, provides that the Notice requiring the hearing shall state:

  1. The portions of the approval or each term or condition and;
  2. The grounds on which the Applicant is required.

in the approval in respect of which the hearing is required.

  1. The grounds on which the Applicant intends to

ely at the hearing in relation to each portion appealed.

The Notice should also include:

  1. The name of the appellant;

  2. The address of the appellant;

  3. The Certificate of Approval number;

  4. The date of the Certificate of Approval;

  5. The name of the Director;

  6. The municipality within which the works are located;

And the Notice should be signed and dated by the appellant.

This Notice must be served upon:

The Secretary, Environmental Appeal Board, 112 St. Clair Avenue West, Suite 502, Toronto, Ontario. M4V 1N3.ANDThe Director, Section 9, Environmental Protection Act, Ministry of Environment and Energy, 250 Davisville Avenue, 3rd Floor, Toronto, Ontario. M4S 1H2

The above noted works are approved under S

ction 9 of the Environmental Protection Act.

DATED AT TORONTO this 7th

day of September, 1993.

QN/an

P. DeAngelis Director, Section 9, Environment

P. Eng. 1 Protection Act.

cc:-Mr. R. Dunn, MOEE, Ottawa District Officer

QQ79 (0420)


NOTICE MINISTRY OF ENVIRONMENT & ENERGY

OCT 10 1995 Town of Smiths Falls 77 Beckwith Street North, Box 695 Smiths Falls, Ontario K7A 4T6

OTTAWA

You are hereby notified that the approval issued under Certificate of Approval No. 8-4041-93-006, dated September 7, 1993, is amended as follows:

Condition No. 3.f. is amended to read:

f. The Company shall submit a report on the Source Testing to the District Officer and the Supervisor not later than four (4) months after completing the Source Testing. The report shall be in the format described in the Source Testing Code, and shall also include, but not be limited to:

i. an executive summary;

ii. records of operating conditions;

iii. the results of dispersion calculations in accordance with Regulation 346 indicating the maximum concentration of the Test Contaminants at the Point of Impingement.

All in accordance with the Application for Approval (Air) and supporting information submitted by the Town of Smiths Falls, dated August 28, 1995, signed by B. Symondson.

All other Terms and Conditions remain unchanged.

This Notice shall constitute part of the approval issued under Certificate of Approval No. 8-4041-93-006, dated September 7, 1993.

In accordance with Section 139 of the Environmental Protection Act, R.S.O. 1990, Chapter E-19, as amended, you may by written notice served upon me and the Environmental Appeal Board within 15 days after receipt of this Notice, require a hearing by the Board. Section 142 of the Environmental Protection Act, provides that the Notice requiring the hearing shall state:

  1. The portions of the approval or each term or condition in the approval in respect of which the hearing is required, and;
  2. The grounds on which you intend to rely at the hearing in relation to each portion appealed.

The Notice should also include:

  1. The name of the appellant;

  2. The address of the appellant;

  3. The Certificate of Approval number;

  4. The date of the Certificate of Approval;

  5. The name of the Director;

  6. The municipality within which the works are located;

And the Notice should be signed and dated by the appellant.

This Notice must be served upon:

The Secretary, Environmental Appeal Board, 112 St. Clair Avenue West, Suite 502, Toronto, Ontario. M4V 1N3ANDThe Director, Section 9, Environmental Protection Act, Ministry of Environment and Energy, 250 Davisville Avenue, 3rd Floor, Toronto, Ontario. M4S 1H2

The above noted works are approved under Section 9 of the Environmental Protection Act.

DATED AT TORONTO this18thday ofSeptember, 1995
THIS IS A TRUE COPY OF THE ORIGINAL NOTICE OF AMENDMENT SIGNED BY P. DEANGELIS, P. ENG.
MAILED ON
BY

SJ/fn

cc: District Manager, MOEE Ottawa District Office


APPENDIX B

Monitoring Data and Comparison to Effluent Limits


Town of Smiths Falls 2021 Performance Assessment Report - WPCP Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

MONTHPLANT FLOWS Minimum Day (m3)PLANT FLOWS Maximum Day (m3)PLANT FLOWS Average (m3)PLANT FLOWS Total (m3)RAW INFLUENT Alkalinity (mg/L)RAW INFLUENT BOD5 (mg/L)RAW INFLUENT BOD5 Loadings (kg/d)RAW INFLUENT CBOD5 (mg/L)RAW INFLUENT CBOD5 Loadings (kg/d)RAW INFLUENT TSS (mg/L)RAW INFLUENT TSS Loadings (kg/d)RAW INFLUENT TP (mg/L)RAW INFLUENT TKN (mg/L)RAW INFLUENT Ammonia (N) - Total (mg/L)RAW INFLUENT Ammonia (N) - Unionized (mg/L)RAW INFLUENT pHRAW INFLUENT Temperature (°C)RAW INFLUENT Nitrate (mg/L)RAW INFLUENT Nitrite (mg/L)
January6,1979,2557,250224,757184.00152.001,102.0362.00449.51195.001,413.793.3519.8013.020.0837.547.804.0600.166
February5,6817,9916,194173,434183.00144.00891.9552.00322.09190.001,176.882.9619.9017.900.0987.457.901.2360.189
March7,09221,58011,663361,559202.00105.001,224.6449.00571.50189.002,204.342.6615.7013.010.0677.477.902.3200.221
April6,67916,7658,702261,058222.00160.001,392.3061.00530.82213.001,853.502.7619.7017.160.0827.389.201.8100.206
May6,01215,9098,926276,714231.00126.001,124.6854.00482.00192.001,713.792.8115.709.240.0427.439.201.6300.200
June2,0899,0556,218186,544204.00122.00758.6245.00279.82190.001,181.462.1212.3010.710.0507.3611.101.0080.133
July5,4129,0876,267194,272187.00148.00927.4986.00538.94253.001,585.503.5823.1014.310.0317.2913.001.2800.209
August5,1739,0095,955184,615188.00153.00911.1679.00470.47255.001,518.602.2524.6011.080.0577.3313.000.8460.136
September4,99811,5076,527195,816199.50187.001,220.5991.00593.98322.002,101.765.5024.0011.600.0657.6110.701.2690.210
October5,56718,6418,090250,789211.00136.001,100.2462.00501.58199.001,609.913.3918.409.080.0507.3311.501.2030.168
November5,70810,5417,827234,813219.00146.001,142.7656.00438.32199.001,557.593.5517.904.570.0297.509.902.1900.276
December6,20817,1469,305288,462228.00136.001,265.5249.00455.96172.001,600.512.2016.807.680.0327.568.202.2400.262
TOTAL66,816156,48592,9252,832,8332,458.501,715.0013,061.97746.005,634.992,569.0019,517.6437.13227.90139.360.68689.25119.4021.0922.376
AVERAGE5,56813,0407,744236,069204.88142.921,088.5062.17469.58214.081,626.473.0918.9911.610.0577.449.951.7580.198
Max7,09221,58011,663361,559231.00187.001,392.3091.00593.98322.002,204.345.5024.6017.900.0987.6113.004.0600.276
Min2,0897,9915,955173,434183.00105.00758.6245.00279.82172.001,176.882.1212.304.570.0297.297.800.8460.133

Annual average flow (m<sup>3</sup> /d): 7,761.19

WPCP rate capacity (m3/d): 14,700

Peak flow (m<sup>3</sup> /d): 21,580

Percentage of rated capacity (%): 52.80

MONTHFINAL EFFLUENT
MONTHAlkalinity (mg/L)Ammonia (N) - Total (mg/L)NH3 Loadings (kg/d)Ammonia (N) - Unionized (mg/L)BOD5 (mg/L)BOD5 Loadings (kg/d)CBOD5 (mg/L)CBOD5 Loadings (kg/d)TSS (mg/L)TSS Loadings (kg/d)TP (mg/L)TP Loadings (kg/d)TKN (mg/L)TKN Loadings (kg/d)pHTemperature (°C)Nitrate (mg/L)Nitrite (mg/L)E. Coli Geomean
MONTHAlkalinity (mg/L)Ammonia (N) - Total (mg/L)NH3 Loadings (kg/d)Ammonia (N) - Unionized (mg/L)BOD5 (mg/L)BOD5 Loadings (kg/d)CBOD5 (mg/L)CBOD5 Loadings (kg/d)TSS (mg/L)TSS Loadings (kg/d)TP (mg/L)TP Loadings (kg/d)TKN (mg/L)TKN Loadings (kg/d)MinAvgMaxTemperature (°C)Nitrate (mg/L)Nitrite (mg/L)
January136.000.0200.150.0033.0021.753.0021.751.107.980.070.510.805.807.087.407.747.2010.600.0481.00
February111.000.0400.250.0003.0018.583.0018.580.583.590.040.250.804.967.127.357.627.2012.500.1421.00
March140.000.0200.230.0003.0034.993.0034.990.9010.500.040.470.708.167.007.217.356.508.950.0611.00
April151.000.0100.090.0003.0026.113.0026.110.928.010.040.350.806.967.097.197.297.809.310.1001.00
May162.300.0600.540.0043.0026.783.0026.780.454.020.030.270.706.257.227.357.468.308.710.0131.00
June125.000.0100.060.0003.0018.653.0018.650.664.120.030.190.704.357.117.328.069.708.880.0631.00
July115.000.0200.130.0103.0018.803.0018.800.724.530.040.250.704.397.187.347.4811.9010.790.0521.00
August110.000.0100.060.0003.0017.873.0017.870.744.410.060.360.704.176.957.237.4111.8011.310.0531.00
September107.700.0200.130.0403.0019.583.0019.580.503.260.050.330.704.577.307.467.749.5012.200.0451.00
October125.000.0200.160.0103.0024.273.0024.270.504.070.050.400.604.857.017.337.557.8011.040.0491.00
November159.000.0500.390.0103.0023.483.0023.480.957.470.050.390.705.487.217.467.978.7010.380.0831.00
December160.000.0100.090.0103.0027.923.0027.920.635.860.030.280.706.517.167.447.696.9010.990.1001.00
TOTAL1,602.000.2902.270.08736.00278.7836.00278.788.6667.810.534.038.6066.4585.4388.0891.36103.30125.660.8112.00
AVERAGE133.5000.0240.1890.0073.00023.2313.00023.2310.7225.6510.0440.3360.7175.5387.1197.3407.6138.60810.4720.0671.000
Max162.300.0600.540.0403.0034.993.0034.991.1010.500.070.510.808.167.307.468.0611.9012.500.141.00
Min107.700.010.060.003.0017.873.0017.870.453.260.030.190.604.176.957.197.296.508.710.011.00
LIMITS2.6/14.038.0/206.015.00220.5015.00220.500.304.406.0 to 9.5200
OBJECTIVES2.0/12.010.005.000.256.5 to 8.5150

NOTE: if cell is highlighted in yellow with red text this is a non-compliance monthly average. Ministry must be notified (verbal & written) as per ECA condtion 10(3) NOTE: if cell is highlighted in orange with bold text this value is above the objectives noted in ECA

Comments: Flows for June 6 and 7 are not correct due to VPN connection issue at WTP


2021 Final Effluent GeoMean

Town of Smiths Falls 2021 Performance Assessment Report - WPCP Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

JANUARY 6-Jan-21Location Final Effluent*Location 1Location CFU/100mL
13-Jan-21Final Effluent*1CFU/100mL
20-Jan-21Final Effluent*1CFU/100mL
27-Jan-21Final Effluent*1CFU/100mL
CFU/100mL
CFU/100mL
CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
FEBRUARY 3-Feb-21Location Final Effluent*Location 1Location CFU/100mL
10-Feb-21Final Effluent*1CFU/100mL
17-Feb-21Final Effluent*1CFU/100mL
24-Feb-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
MARCH 3-Mar-21Location Final Effluent*Location 1Location CFU/100mL
10-Mar-21Final Effluent*1CFU/100mL
17-Mar-21Final Effluent*1CFU/100mL
24-Mar-21Final Effluent*1CFU/100mL
31-Mar-21Final Effluent*1CFU/100mL
CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
APRIL 7-Apr-21Location Final Effluent*Location 1Location CFU/100mL
14-Apr-21Final Effluent*1CFU/100mL
21-Apr-21Final Effluent*1CFU/100mL
28-Apr-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
MAY 5-May-21Location Final Effluent*Location 1Location CFU/100mL
12-May-21Final Effluent*1CFU/100mL
19-May-21Final Effluent*1CFU/100mL
26-May-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
JUNE 2-Jun-21Location Final Effluent*Location 1Location CFU/100mL
9-Jun-21Final Effluent*1CFU/100mL
16-Jun-21Final Effluent*1CFU/100mL
23-Jun-21Final Effluent*1CFU/100mL
30-Jun-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
JULY Location
7-Jul-21Final Effluent*1CFU/100mL
14-Jul-21Final Effluent*1CFU/100mL
21-Jul-21Final Effluent*1CFU/100mL
28-Jul-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
AUGUST 4-Aug-21Location Final Effluent*Location 1Location CFU/100mL
11-Aug-21Final Effluent*1CFU/100mL
18-Aug-21Final Effluent*1CFU/100mL
25-Aug-21Final Effluent*1CFU/100mL
CFU/100mL
CFU/100mL
CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
SEPTEMBER 1-Sep-21Location Final Effluent*Location 1Location CFU/100mL
8-Sep-21Final Effluent*1CFU/100mL
15-Sep-21Final Effluent*1CFU/100mL
22-Sep-21Final Effluent*1CFU/100mL
29-Sep-21Final Effluent*1CFU/100mL
GEO MEAN1CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
OCTOBER Location
6-Oct-21Final Effluent*1CFU/100mL
13-Oct-21Final Effluent*1CFU/100mL
20-Oct-21Final Effluent*1CFU/100mL
27-Oct-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
NOVEMBER 3-Nov-21Location Final Effluent*Location 1Location CFU/100mL
10-Nov-21Final Effluent*1CFU/100mL
17-Nov-21Final Effluent*1CFU/100mL
24-Nov-21Final Effluent*1CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
DECEMBER 1-Dec-21Location Final Effluent*Location 1Location CFU/100mL
8-Dec-21Final Effluent*1CFU/100mL
15-Dec-21Final Effluent*1CFU/100mL
22-Jan-21Final Effluent*1CFU/100mL
29-Jan-21Final Effluent*1CFU/100mL
CFU/100mL
CFU/100mL
GEO MEAN1.00CFU/100mL
Min1CFU/100mL
Max1CFU/100mL
  • indicates sample result was 0 cfu/100mL, round up to 1 for geomean calculation

Smiths Falls WPCP Final Effluent Flow (m3) 2017 to 2021

CategoryWPCP Maximum Flow (m3)WPC Average Flow (m3)WPCP Rated Capacity (m3/day)
Jan-17188001220014800
Feb-17238001240014800
Mar-17268001470014800
Apr-17458001700014800
May-17560001880014800
Jun-1746000890014800
Jul-17133001430014800
Aug-17165001150014800
Sep-1710800770014800
Oct-1737200860014800
Nov-17255001320014800
Dec-1712700940014800
Jan-18345001300014800
Feb-18360001500014800
Mar-18168001330014800
Apr-18312001880014800
May-18163001040014800
Jun-1815300800014800
Jul-1810800660014800
Aug-189800670014800
Sep-1813200740014800
Oct-1812300750014800
Nov-18175001060014800
Dec-18240001300014800
Jan-19200001000014800
Feb-1915300940014800
Mar-19407001480014800
Apr-19317001800014800
May-19153001150014800
Jun-1913200910014800
Jul-1910200700014800
Aug-1910200640014800
Sep-1912000700014800
Oct-1920000970014800
Nov-19225001060014800
Dec-19160001080014800
Jan-20340001380014800
Feb-20118001000014800
Mar-20272001620014800
Apr-20158001180014800
May-2017500950014800
Jun-209100690014800
Jul-209100640014800
Aug-20257001100014800
Sep-2013700760014800
Oct-2015000830014800
Nov-2014200770014800
Dec-20320001120014800
Jan-219300720014800
Feb-218000610014800
Mar-21215001180014800
Apr-2116800870014800
May-2115800880014800
Jun-219100610014800
Jul-219100620014800
Aug-219000580014800
Sep-2111500650014800
Oct-2118700810014800
Nov-2110600780014800
Dec-2117200940014800

Town of Smiths Falls 2021 Performance Assessment Report - WPCP Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

Smiths Falls WPCP Yearly Overview 2017 to 2021

YearWPCP Average Flow (m3)WPCP Maximum Flow (m3)WPCP Rated Capacity (m3/day)Percent of Rated Capacity (%, rhs)
201712300560001460082.2
201810800360001460073.3
201910300408001460070.5
202010000340001460067.8
20217700215001460055

APPENDIX C

Maintenance Records


Town of Smiths Falls 2021 Performance Assessment Report - WPCP Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

DateAsset IDAsset CategoryAsset DescMaintenar Maintenance Sub TypeCompleted By MB/TGDescription of Maintenance Required No dataComments (1) Condensate probe was dirty giving false water level readings, needed to be cleanedComments (2) No data
22-Dec-21WPCPAsset-00394InstrumentationLT1210Corrective InspectionMolly and SteveReplace lamp on module 1 lamp 6No dataNo data
21-Dec-21WPCPAsset-0192UV LampsUV632Corrective RepairSteve L. / T. GeorgeMotor seized, replace motor, pulleys and belt.No dataTested ok
17-Dec-21WPCPAsset-0035MotorM111Corrective RepairA MorrisKilmarnock on-site Tuesday Dec 7 to install new hardware on both vibrating sifter motorsNo dataOperated motors for 30 minutes and checked hardware torque-ok
09-Dec-21WPCPAsset-0239SizerM1430Corrective RepairKilmarnock AaronBearings shot, replace lower motor.No dataNo data
27-Nov-21WPCPAsset-0239SizerM1430Corrective RepairMolly and SteveChange lamp on module 7 lamp 2No dataNo data
20-Nov-21WPCPAsset-0192UV LampsUV632Corrective RepairSteve LReplace broken beltNo dataNo data
15-Nov-21WPCPAsset-0036Odour ControlSCRUB101Corrective RepairTG/MB/AM/MMReplaced rotor and stator on press feed pumpNo dataNo data
09-Nov-21WPCPAsset-0204PumpM3020Corrective RepairS.Laplante & T. GeorgeReplace lamp 4/4 & 5/5No dataNo data
25-Nov-21WPCPAsset-0192UV LampsUV632Corrective RepairSteve, MattTripping out, gear box noisy. Replace SEW drive with Nord gear drive from stock.No dataNo data
29-Oct-21WPCPAsset-0212MixerM3040Corrective RepairTG/SLReplace bulb in module 4 lamp 4No dataNo data
24-Oct-21WPCPAsset-0192UV LampsUV632Corrective RepairSteve LaPlanteReplace seal and bearings on input shaft and replace pulleys (put used ones on) replace belt, top up with 220. Order new pulleys.Order new pulleysNo data
18-Oct-21WPCPAsset-0035Grit RemovalM111Corrective RepairMolly and MattReplace lightbulb on module 1 lamp 1No dataNo data
18-Oct-21WPCPAsset-00021-2UVUV631Corrective RepairMollyShear pinNo dataNo data
18-Oct-21WPCPAsset-0082Drive UnitM207Corrective RepairAaron SteveReplaced shear pinReplaced shear pinNo data
08-Oct-21WPCPAsset-0250Drive UnitM502Corrective RepairSteve LaplanteUV lamp out bank B module 9, lamp 6.Change lamp B, #6No data
05-Oct-21WPCPAsset-0192UV LampsUV632Corrective RepairTG MM SLKilmarnock onsite for new roller and bearing installation and alignmentNo dataCompleted - 5 days. 3 new rollers in order
20-Sep-21WPCPAsset-00392-2DecanterBeltpressCorrective RepairMM TG SL MBInspection and diagnosis required. Forklift not running properlyAppears to be an issue with the computer. Lightning bolt visible on dash. SL contacted HanslerHandler in for repair
02-Sep-21WPCPAsset-00002-2OtherLindeCorrective RepairSLBattery replacement requiredPositive terminal on battery disconnected, replacement requiredBattery replaced
02-Sep-21WPCPAsset-00001-2OtherClarkeCorrective RepairAMacNCoolant Leak, requires repair/replacement of fittings.Tandem on site to perform repair.Unit run and brought up to temperature. Leaks repaired.
19-Aug-21WPCPAsset-00390GeneratorDiesel GenCorrective RepairAMacNMixer failed July 5, 2021. Require complete replacement with new unit.New Unit installed. New anchors installed. Oil added.Kilmarnock installed. Unit bump tested to verify operation. All ok.
19-Aug-21WPCPAsset-0197MixerM920Corrective RepairMMPatches of concrete walkway infront of Alum building degrading. Patch work required.Trip hazards and edges marked with hi-vis spray paint in the interim. Staff on site notified.No data
04-Aug-21WPCPAsset-0000WWTPWastewaterCorrective RepairMolly and SteveReplace lamp 3 in module 4No dataNo data
10-Jul-21WPCPAsset-00021-2UVUV631Corrective RepairMollyReplace gasket on buckets elevatorNo dataNo data
09-Jul-21WPCPAsset-0238Bucket ElevatorBE1420Corrective RepairMollyChange out teeth on muffin monsterNo dataNo data
09-Jul-21WPCPAsset-0203GrinderGrind3020Corrective RepairMollyChange out old plug valve with new plug valveNo dataNo data
09-Jul-21WPCPAsset-0205ValveV901Corrective RepairTG, AmacN, MBTighten a loose fitting which was causing the leakNo dataNo data
06-Jul-21WPCPAsset-0107PumpM422Corrective RepairSteveChange gasket on blowerSmall tear in gasket causing a small air leakNo data
05-Jul-21WPCPAsset-0099BlowerM403Corrective RepairMollyReplaced bulb in module 5 lamp 1 at 11691 hourNo dataNo data
28-Jun-21WPCPAsset-00021-2UVUV631Corrective RepairMolly and AndrewReplace broken shear bolt on south bridge breakerNo dataNo data
23-Jun-21WPCPAsset-0217PumpM3050Corrective RepairM. B., S.L.Sludge tank 2 mixer broken, needs replaced or repairedHousing being sent to kilmarnock for repairs.All ok. Replaced with new unit. New shaft. All ok
12-Jun-21WPCPAsset-0199MixerM930Corrective RepairAMacNSludge andன்னer breaker in the fireplace.No dataNo data
01-Jun-21WPCPAsset-0081Drive UnitM206Corrective RepairMolly and AndrewChanged broken shear pinNo dataNo data
25-May-21WPCPAsset-0192UV LampsUV632Corrective RepairMolly and JenniReplaced bulb in module 7 lamp 3No dataNo data
14-May-21WPCPAsset-0184MixerM602Corrective InspectionSteve LNo dataRemove old grease from upper gear reducer and fill with new and inspectNo data

2021 Maintenance - Corrective

27-Apr-21WPCPAsset-0192UV LampsUV632Corrective RepairMolly and TylerReplace lamps in module 3 sleeves 4/6 and module 7 sleeve 4No dataNo data
15-Apr-21WPCPAsset-0036Odour ControlSCRUB101Corrective RepairSteve LaPlanteBroken beltChange belt B42N/A
06-Apr-21WPCPAsset-0007PumpM103Corrective RepairMolly and AndrewWinding temp sensor not online possible bad connection or wire.Pump sent to Hewitt's for repairPump sent to Hewitt's for repair
24-Mar-21WPCPAsset-0002-zTankHWT-PelleCorrective RepairAMacNReplace leaking Hot Water TankPUBLOWS called March 24, 2021Completed Friday
23-Mar-21WPCPAsset-0184MixerM602Corrective RepairTG AMacDrained oil and cleaned gear, and replaced with new oilTop spring seal, could be replaced with new oilPlaced back in service
15-Mar-21WPCPAsset-0122PumpM406Corrective RepairMolly and JenniRepair leak on RAS pump 3Faster dripCompleted by Kilmarnock
03-Mar-21WPCPAsset-0192UV LampsUV632Corrective RepairJY/ SLReplaced ballast for bank B module 5 lamp 1/2No dataNo data
02-Mar-21WPCPAsset-0192UV LampsUV632Corrective RepairJY/SLTest channel 1 bank B ballast faultK308C036 - 10,408 hrs March 3rd replacedAll good
18-Feb-21WPCPAsset-0230CycloneCyclone11Corrective RepairAMacN,MBDue to failure, replacement of 2 of 11 Goyen dust collector valves require replacing.Replaced Valve number 4 and number 8.No data
18-Feb-21WPCPAsset-0225MotorM1120Corrective RepairAMacN, MBReplace 2 x B45 belts. Adjust motor tension and test.Both belts cracked throughout.All ok.
18-Feb-21WPCPAsset-0243MotorM1460Corrective RepairAMacN, MBReplace 3 x AP80 belts. Adjust motor to proper tension and test.All ok. Note, one belt blown, one stretched and one operating.All ok
11-Feb-21WPCPAsset-0243MotorM1460Corrective RepairAMacN, MBReplaced 3 belts. SIZE A80One broken, one stretched, one operating unit.No data
11-Feb-21WPCPAsset-0239SizerM1430Corrective RepairAMacN, MBReplace oversized and target screens.No stock left. Will require new screens to be made up.Top screen required extra bend in connection to stay secured
11-Feb-21WPCPAsset-0239SizerM1430Corrective RepairMolly and AndrewReplaced screens for oversized and target screensBoth had tearsNo data
11-Feb-21WPCPAsset-00392DecanterBeltpressCorrective InspectionKilmarnock Ent.No dataNo dataComplete inspection for future work.
04-Feb-21WPCPAsset-00392DecanterBeltpressCorrective RepairAM/SL/TG/MBReplaced Top BeltNo dataBelt replaced - no other issues
22-Jan-21WPCPAsset-00422OtherAuto-GateCorrective RepairSLGate tripping outGate overshooting and overloading motorAll fixed travel guides adjusted
20-Jan-21WPCPAsset-00419PipingHPEW PipiCorrective RepairSteve LaPlanteReplace 1" cam lock fitting at hose bib.Part installed is temporarily aluminum.No data
19-Jan-21WPCPAsset-0249UV LampsUV631Corrective RepairAMacN, TG, SLModule 8, Ballast 3, for lamps 5 & 6 requires replacementJob completed by EmTech.All ok, unit in service and alarm cleared.
15-Jan-21WPCPAsset-00392DecanterBeltpressCorrective RepairTG,SL,MM,AMacNChange Bottom Belt1.5 hoursNo data

Town of Smiths Falls 2021 Performance Assessment Report - WPCP Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

DateAsset IDAsset CategoryAsset DescriptionMaintenance TypeMaintenance Sub TypeCompleted ByDescription of Maintenance RequiredComments (1)Comments (2)
31-Dec-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
30-Dec-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataRan well
30-Dec-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased and tested
29-Dec-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged and tested
29-Dec-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged and tested
24-Dec-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataAll entered
24-Dec-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataGreased
23-Dec-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
21-Dec-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectMolly BucklandNo dataNo dataInspected and no need to be replaced
21-Dec-21WPCPAsset-0239SizerM1430PreventativeClean and InspectMolly BucklandNo dataNo dataAll okay
20-Dec-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingMolly BucklandNo dataNo dataNo data
20-Dec-21WPCPAsset-00412InstrumentatiLAB Spectro WPCPPreventativeVerificationMolly BucklandNo dataNo dataNo data
20-Dec-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataMolly on call
20-Dec-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataMolly on call

2021 Maintenance - Preventative

18-Dec-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationTyler GeorgeNo dataNo dataEntered
17-Dec-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalTyler GeorgeNo dataNo dataChecked
17-Dec-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAaron MorrisNo dataNo dataDone -ok
16-Dec-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectJason BarlowNo dataNo dataTG completed Dec 13th
16-Dec-21WPCPAsset-00016-2021-03-09T07:08:25-05:00OtherRAS (building)PreventativeClean and InspectTyler GeorgeNo dataNo dataCompleted
16-Dec-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataCompleted
14-Dec-21WPCPAsset-0035Grit RemovalM111PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
13-Dec-21WPCPAsset-0050InstrumentatiFT128PreventativeCalibrationJason BarlowNo dataNo dataCompleted by tower electronics
13-Dec-21WPCPAsset-00399Flow MeterFT617PreventativeCalibrationJason BarlowNo dataNo dataCompleted by tower electronics
13-Dec-21WPCPAsset-00397Flow MeterFT507PreventativeCalibrationJason BarlowNo dataNo dataCompleted by tower electronics
13-Dec-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationJason BarlowNo dataNo dataChanged
13-Dec-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataChanged
11-Dec-21WPCPAsset-0000WWTPWPCPPreventativeClean and InspectJason BarlowNo dataNo dataCompleted by Solid State Electric
10-Dec-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalSteve LaPlanteNo dataNo dataAll good
10-Dec-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectAaron MorrisNo dataNo dataAll ok
10-Dec-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAaron MorrisNo dataNo dataAll ok
10-Dec-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectAaron MorrisNo dataNo dataGreased belt press and some of the pelletizer equipment.
06-Dec-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMatt MensenNo dataNo dataChanged & Tested

2021 Maintenance - Preventative

06-Dec-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMatt MensenNo dataNo dataChanged & Tested
06-Dec-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectMatt MensenNo dataNo dataNot required
03-Dec-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
02-Dec-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataSuccessful
30-Nov-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAaron MorrisNo dataEverything okEverything ok
29-Nov-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataNot req'd
29-Nov-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataNot req'd
26-Nov-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
26-Nov-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll good
25-Nov-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
22-Nov-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChange
22-Nov-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
19-Nov-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAaron MorrisNo dataNo dataNo issues
19-Nov-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationAaron MorrisNo dataAll data enteredAll data entered
19-Nov-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalAaron MorrisNo dataNo dataAll ok
17-Nov-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectMolly BucklandNo dataNo dataCompleted by Matt
17-Nov-21WPCPAsset-0239SizerM1430PreventativeClean and InspectMolly BucklandNo dataNo dataCompleted by Matt

2021 Maintenance - Preventative

16-Nov-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectMolly BucklandNo dataNo dataOkay
15-Nov-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingOperators Waste Water PlantNo dataNo dataNo data
15-Nov-21WPCPAsset-00412InstrumentationLAB Spectro WPCPPreventativeVerificationOperators Waste Water PlantNo dataNo dataNo data
15-Nov-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataOkay
15-Nov-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataOkay
12-Nov-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalTyler GeorgeNo dataNo dataTested
12-Nov-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationTyler GeorgeNo dataNo dataEntered 11-01-21-11-05-21
11-Nov-21WPCPAsset-00401PumpM3020PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
08-Nov-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMatt MensenNo dataNo dataChanged
08-Nov-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMatt MensenNo dataNo dataChanged
05-Nov-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataOil
04-Nov-21WPCPAsset-00401PumpM3020PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
04-Nov-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalTyler GeorgeNo dataNo dataTested not under load
01-Nov-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataComplete
01-Nov-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
01-Nov-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged

29-Oct-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectAaron MorrisNo dataNo dataGreased belt press and pelletizer equipment. All Ok
28-Oct-21WPCPAsset-00394InstrumentationLT1210PreventativeClean and InspectMolly BucklandNo dataNo dataCompleted
27-Oct-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataTightened and greased
25-Oct-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged/tested
25-Oct-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataTestedChanged
25-Oct-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataMolly
23-Oct-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataComplete
22-Oct-21WPCPAsset-0192UV LampsUV632PreventativeClean and InspectMolly BucklandNo dataNo dataCompleted
20-Oct-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMatt MensenNo dataNo dataGreased
20-Oct-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectMatt MensenNo dataNo dataCleaned
20-Oct-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectMatt MensenNo dataNo dataCleaned
19-Oct-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
19-Oct-21WPCPAsset-00380BuildingRaw SludgePreventativeOperationalMatt MensenNo dataNo dataGreased/Exercised
19-Oct-21WPCPAsset-0014Bar Screenscreen2PreventativeClean and InspectMatt MensenNo dataNo dataGreased
19-Oct-21WPCPAsset-0013Bar Screenscreen1PreventativeClean and InspectMatt MensenNo dataNo dataGreased
18-Oct-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataCompleted
18-Oct-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataCompleted
18-Oct-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectMolly BucklandNo dataNo dataCompleted by TG on October 15

14-Oct-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationTyler GeorgeNo dataNo dataWatertrax entered
14-Oct-21WPCPAsset-00401PumpM3020PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
14-Oct-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectTyler GeorgeNo dataNo dataInspected
14-Oct-21WPCPAsset-0239SizerM1430PreventativeClean and InspectTyler GeorgeNo dataNo dataChecked
12-Oct-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalTyler GeorgeNo dataNo dataRunning, no load
12-Oct-21WPCPAsset-00412InstrumentatiLAB Spectro WPCPPreventativeVerificationTyler GeorgeNo dataNo dataNo data
12-Oct-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataChanged
12-Oct-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataChanged
12-Oct-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingTyler GeorgeNo dataNo dataNo data
10-Oct-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
07-Oct-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMatt MensenNo dataNo dataGreased
04-Oct-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMatt MensenNo dataNo dataTested
04-Oct-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectMatt MensenNo dataNo dataCompleted
04-Oct-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataChanged, testedChanged, tested
04-Oct-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataChanged and testedChanged, tested
03-Oct-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMatt MensenNo dataNo dataEntered
29-Sep-21WPCPAsset-00022-2021-09-29T12:52:58-04:00Pelletizer1510 - Dust CollectorPreventativeClean and InspectOperators Waste Water PlantNo dataReplaced filtersReplaced 30 Filters and clean
29-Sep-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataGreased and packing tightenedGreased and packing tight

2021 Maintenance - Preventative

29-Sep-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectSteve LaPlanteNo dataGreasedGreased
25-Sep-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMatt MensenNo dataChanged Sept.24.21Changed/Tested
25-Sep-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMatt MensenNo dataChanged Sept.24.21Changed/Tested
23-Sep-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperational CalibrationSteve LaPlanteNo dataTestedAll good
23-Sep-21WPCPAsset-00017-2021-03-15T13:12:00-04:00SamplerSamplersPreventativeCalibrationSteve LaPlanteNo dataNo dataCompleted
21-Sep-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationTyler GeorgeNo dataNo dataComplete
19-Sep-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataChanged
16-Sep-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataChanged
14-Sep-21WPCPAsset-00016-2021-03-09T07:08:25-05:00OtherRAS (building)PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
14-Sep-21WPCPAsset-0035Grit RemovalM111PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
14-Sep-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectTyler GeorgeNo dataNo dataCompleted
14-Sep-21WPCPAsset-00401PumpM3020PreventativeClean and InspectTyler GeorgeNo dataNo dataGreased
14-Sep-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalTyler GeorgeNo dataNo dataTested
14-Sep-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectTyler GeorgeNo dataNo dataCleaned
13-Sep-21WPCPAsset-0249UV LampsM501PreventativeClean and InspectJason BarlowNo dataNo dataCompleted sept 10th, 2021
12-Sep-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataUpdated

2021 Maintenance - Preventative

12-Sep-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationTyler GeorgeNo dataNo dataUpdated
10-Sep-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataCompleted
09-Sep-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectMolly BucklandNo dataNo dataCompleted
09-Sep-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataGreased and tightened packing
09-Sep-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
09-Sep-21WPCPAsset-0239SizerM1430PreventativeClean and InspectMolly BucklandNo dataNo dataCompleted by MB/TG
09-Sep-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectMolly BucklandNo dataNo dataCompleted by MB/TG
07-Sep-21WPCPAsset-00412InstrumentatiLAB Spectro WPCPPreventativeVerificationMolly BucklandNo dataNo dataNo data
07-Sep-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataCompleted the week of August30-September 3
07-Sep-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingMolly BucklandNo dataNo dataNo data
07-Sep-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataChanged
07-Sep-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataChanged
04-Sep-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
02-Sep-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMatt MensenNo dataNo dataAll Good
02-Sep-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectMolly BucklandNo dataNo dataCompleted
02-Sep-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectMolly BucklandNo dataNo dataCompleted
30-Aug-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
30-Aug-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged

27-Aug-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased 3 fittings
24-Aug-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataRuns wellRan and inspected
24-Aug-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataEnteredEntered
23-Aug-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataUpdated
23-Aug-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataUpdated
18-Aug-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectMolly BucklandNo dataNo dataHosed
17-Aug-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectMolly BucklandNo dataNo dataHosed
17-Aug-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataGreased
17-Aug-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
16-Aug-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
16-Aug-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
12-Aug-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataData entered
12-Aug-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
12-Aug-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataTested
10-Aug-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged

2021 Maintenance - Preventative

10-Aug-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
06-Aug-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataAll entered
05-Aug-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataGreased
05-Aug-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
05-Aug-21WPCPAsset-0239SizerM1430PreventativeClean and InspectMatt MensenNo dataAll GoodInspected & Cleaned
05-Aug-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectMatt MensenNo dataAll GoodInspected
03-Aug-21WPCPAsset-00412InstrumentatiLAB Spectro WPCPPreventativeVerificationMolly BucklandNo dataNo dataNo data
03-Aug-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataChanged
03-Aug-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataChanged
30-Jul-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataEnteredEntered
29-Jul-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
29-Jul-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectMolly BucklandNo dataNo dataGreased
28-Jul-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectMolly BucklandNo dataNo dataHosed
27-Jul-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectMolly BucklandNo dataNo dataAll okay
27-Jul-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataGreased
27-Jul-21WPCPAsset-00394InstrumentationLT1210PreventativeClean and InspectMolly BucklandNo dataNo dataOpened hatch and cleaned inside
26-Jul-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataMatt to SteveChanged Matt to Steve

2021 Maintenance - Preventative

26-Jul-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataMatt to SteveChanged Matt to Steve
26-Jul-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingMolly BucklandNo dataNo dataNo data
23-Jul-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataRecordedRecorded
21-Jul-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataAll is wellRun good
20-Jul-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectMatt MensenNo dataNo dataCleaned
20-Jul-21WPCPAsset-00380BuildingRaw SludgePreventativeOperationalMatt MensenNo dataNo dataGreased/Exercised
20-Jul-21WPCPAsset-0014Bar Screenscreen2PreventativeClean and InspectMatt MensenNo dataNo dataGreased
20-Jul-21WPCPAsset-0013Bar Screenscreen1PreventativeClean and InspectMatt MensenNo dataNo dataGreased
20-Jul-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectSteve LaPlanteNo dataNo dataCleaned
20-Jul-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMatt MensenNo dataAll GoodGreased/Tighten
19-Jul-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationMatt MensenNo dataTestedChanged
19-Jul-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataDoneChanged to Matt
19-Jul-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataDoneChanged to Matt
16-Jul-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataEnteredEntered
15-Jul-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataOkRan good
12-Jul-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataChangedUpdated

2021 Maintenance - Preventative

12-Jul-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
12-Jul-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
09-Jul-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataAll entered
08-Jul-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalMolly BucklandNo dataNo dataAll okay
08-Jul-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataGreasedGrease all fittings
05-Jul-21WPCPAsset-0239SizerM1430PreventativeClean and InspectMatt MensenNo dataCleanedInspected
05-Jul-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectMatt MensenNo dataAll GoodInspected
05-Jul-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataAll good
05-Jul-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataAll goods
02-Jul-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationMolly BucklandNo dataNo dataAll entered
02-Jul-21WPCPAsset-00401PumpM3020PreventativeClean and InspectMolly BucklandNo dataNo dataGreased and tightened packing
02-Jul-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataTested okTested ok
29-Jun-21WPCPAsset-00412InstrumentatiLAB Spectro WPCPPreventativeVerificationMolly BucklandNo dataNo dataNo data
28-Jun-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationMolly BucklandNo dataNo dataTested
28-Jun-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationMolly BucklandNo dataNo dataTested
28-Jun-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectMolly BucklandNo dataNo dataCompleted by TG
28-Jun-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectMolly BucklandNo dataCompleted by TGAll good

2021 Maintenance - Preventative

25-Jun-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodGreased/Tighten
25-Jun-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataCompleted
25-Jun-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataAll GoodRan/tested
22-Jun-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataCompleted on June 15 by TG
21-Jun-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataCompleted
21-Jun-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataCompleted
21-Jun-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectOperators Waste Water PlantNo dataCompletedHose down filter walls
18-Jun-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataCompletedCompleted
18-Jun-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
15-Jun-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingOperators Waste Water PlantNo dataNo dataNo data
15-Jun-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataAll okay
14-Jun-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
14-Jun-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
14-Jun-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataChanged
10-Jun-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodCleaned
09-Jun-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataAll GoodTested

2021 Maintenance - Preventative

09-Jun-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodInspected/Greased
09-Jun-21WPCPAsset-0035Grit RemovalM111PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodInspected/Greased
08-Jun-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationAndrew MacNaughtonNo dataNo dataCompleted and tested
08-Jun-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationAndrew MacNaughtonNo dataNo dataComplete and tested
08-Jun-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataTested
07-Jun-21WPCPAsset-00016-2021-03-09T07:08:25:05:00OtherRAS (building)PreventativeClean and InspectOperators Waste Water PlantNo dataGreased/ExercisedCompleted
05-Jun-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataCompleted
04-Jun-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataRan by Tandef after maintenance
04-Jun-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataCoolant leak
02-Jun-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll done
31-May-21WPCPAsset-00001-2021-05-21T13:56:37:04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataTested
31-May-21WPCPAsset-00003-2021-05-21T14:01:17:04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataTested
28-May-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataAll entered
28-May-21WPCPAsset-00412Instrumentation onLAB Spectro WPCPPreventativeVerificationOperators Waste Water PlantNo dataNo dataNo data
28-May-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodGreased/Tightened

28-May-21WPCPAsset-0239SizerM1430PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodInspected & Cleaned
28-May-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodInspected
27-May-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataAll okay
25-May-21WPCPAsset-00001-2021-05-21T13:56:37-04:00AlarmSFWWS1\WIN911PreventativeVerificationOperators Waste Water PlantNo dataNo dataCompleted
25-May-21WPCPAsset-00003-2021-05-21T14:01:17-04:00AlarmSFWWS2\WIN911PreventativeVerificationOperators Waste Water PlantNo dataDoneCompleted
23-May-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataCompleted
21-May-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataSolid State tested with new controller15min
21-May-21WPCPAsset-00382InstrumentationH2S BPRPreventativeCalibrationOperators Waste Water PlantNo dataNo dataNo data
18-May-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodOiled & Greased
18-May-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodTightened & Greased
18-May-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectOperators Waste Water PlantNo dataAll GoodInspected & greased
17-May-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll hosed
15-May-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataMay 14/2021Entered
13-May-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataHosed/Cleaned
11-May-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataAll okay
11-May-21WPCPAsset-00394InstrumentationLT1210PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataNo data
10-May-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataHosed/Cleaned

2021 Maintenance - Preventative

10-May-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataCompleted - Greased
10-May-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingOperators Waste Water PlantNo dataNo dataNo data
10-May-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataAll has been entered
06-May-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalJenni YuillNo dataNo dataRan for 1 hr no issues, not under load
04-May-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased fittings
30-Apr-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataAll sheets have been entered
29-Apr-21WPCPAsset-00050-2021-03-18T10:09:58-04:00TankWET WELLPreventativeClean and InspectAustin MitchellNo dataNo dataWet Well 1 cleaned by CWW. Completed April 28 & 29, 2021
29-Apr-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAustin MitchellNo dataNo dataGreased press feed pump bearings and stuffing box
29-Apr-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataAll ok
23-Apr-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataData EnteredLab Data Entry
23-Apr-21WPCPAsset-00380BuildingRaw Sludge (Building)PreventativeOperationalOperators Waste Water PlantNo dataCompleted by MM/AMGreased
23-Apr-21WPCPAsset-0197MixerM920PreventativeClean and InspectOperators Waste Water PlantNo dataOil changedCompleted
23-Apr-21WPCPAsset-0197MixerM920PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataCompleted
23-Apr-21WPCPAsset-0239SizerM1430PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataEverything looked good
23-Apr-21WPCPAsset-0014Bar Screenscreen2PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
23-Apr-21WPCPAsset-0013Bar Screenscreen1PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
23-Apr-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataAll GoodTested
23-Apr-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectOperators Waste Water PlantNo dataChanged mufflers #10 & 11Inspected by MM/MB

2021 Maintenance - Preventative

20-Apr-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataDone
20-Apr-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectAustin MitchellNo dataNo dataNorth and South Filter walls hosed. Disinfection backwash on going South Filter.
20-Apr-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectAustin MitchellNo dataNo dataHosed North and South Primary Weirs
19-Apr-21WPCPAsset-00412InstrumentationLAB Spectro WPCPPreventativeVerificationOperators Waste Water PlantNo dataNo dataNo data
16-Apr-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationSteve LaPlanteNo dataNo dataDone
15-Apr-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectAustin MitchellNo dataNo dataGreased belt press roller bearings
15-Apr-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAustin MitchellNo dataNo dataGreased Press feed pump
15-Apr-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalSteve LaPlanteNo dataAll is wellStarts and runs, but continue to leave in manual start mode.
14-Apr-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataCompleted
09-Apr-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataDone
07-Apr-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingOperators Waste Water PlantNo dataNo dataNo data
07-Apr-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll okay
01-Apr-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalAndrew MacNaughtonNo dataRun for 20 minutes not under load. No issues with run.All ok
30-Mar-21WPCPAsset-00018-2021-03-30T10:51:58-04:00AugerFarm King Outdoor AugerPreventativeOperationalOperators Waste Water PlantNo dataCompleted. Tech verified operation, all parts ok. Belts ok. Unit greased.Unit frozen in ice upon inspection.
30-Mar-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataLab data entered for Week of March 22, 2021
26-Mar-21WPCPAsset-00401PumpM3020PreventativeClean and InspectAndrew MacNaughtonNo dataWith TGComplete

2021 Maintenance - Preventative

24-Mar-21WPCPAsset-0239SizerM1430PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll okay
19-Mar-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataVolatiles and in house lab sheet all put into watertrax for the week of March 15-19
18-Mar-21WPCPAsset-0187Travelling BridgeCP605PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataCompleted by MB/JY
18-Mar-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalJenni YuillNo dataNo dataRan 10mins not under load
16-Mar-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
16-Mar-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectOperators Waste Water PlantNo dataAll mufflers function properly, aside from #10 which is turned offInspected
16-Mar-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll chains oiled
15-Mar-21WPCPAsset-00017-2021-03-15T13:12:00-04:00SamplerSamplersPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataChanged tubing and calibrated samplers
15-Mar-21WPCPAsset-00017-2021-03-15T13:12:00-04:00SamplerSamplersPreventativeCalibrationOperators Waste Water PlantNo dataNo dataReplaced tubing and calibrated each sampler
12-Mar-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalJenni YuillNo dataNo dataRan not under load for 25mins
12-Mar-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationJenni YuillNo dataNo dataEntered weeks lab data
11-Mar-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectJenni YuillNo dataNo dataCleaned all secondary weirs
09-Mar-21WPCPAsset-0035Grit RemovalM111PreventativeClean and InspectOperators Waste Water PlantNo dataGreased grit snail and Bar screenCleaned, greased, inspected for grit build up
09-Mar-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataGreased fittings on pumpNo leaks
09-Mar-21WPCPAsset-00016-2021-03-09T07:08:25-05:00OtherRAS (building)PreventativeClean and InspectOperators Waste Water PlantNo dataGreased and inspected all plug valves and check valvesSeveral plug valves not taking grease
05-Mar-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationJenni YuillNo dataNo dataEntered all lab data

2021 Maintenance - Preventative

05-Mar-21WPCPAsset-00412Instrumentation onLAB Spectro WPCPPreventativeVerificationOperators Waste Water PlantNo dataNo dataNo data
05-Mar-21WPCPAsset-0000WWTPWPCPPreventativeAlarm TestingOperators Waste Water PlantNo dataNo dataNo data
05-Mar-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalJenni YuillNo dataNo dataRan for 20 mins not under load
03-Mar-21WPCPAsset-00412InstrumentatiLAB Spectro WPCPPreventativeVerificationJenni YuillNo dataNo dataNo data
03-Mar-21WPCPAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataNot Required
03-Mar-21WPCPAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataNot Required
03-Mar-21WPCPAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectJason BarlowNo dataMB/AMCompleted
03-Mar-21WPCPAsset-00401PumpM3020PreventativeClean and InspectJason BarlowNo dataAM/MBCompleted
19-Feb-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataFeb. 19,2021
19-Feb-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataRan wellStarted and ran well
18-Feb-21WPCPAsset-00381Instrumentation onBelt Press Room Hydrogen Sulifide DetectorPreventativeVerificationOperators Waste Water PlantNo dataUnit verified Feb. 11, 2021.All ok.
18-Feb-21WPCPAsset-00381Instrumentati onBelt Press Room Hydrogen Sulifide DetectorPreventativeCalibrationOperators Waste Water PlantNo dataNo dataNo data
12-Feb-21WPCPAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataData entered into Watertrax.
12-Feb-21WPCPAsset-00378PelletizerPelletizerPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataOiled all chains
11-Feb-21WPCPAsset-0239SizerM1430PreventativeClean and InspectAndrew MacNaughtonNo data2 screens replaced. See CM log.Inspected.
11-Feb-21WPCPAsset-0242RedlerRed1450PreventativeOperationalAndrew MacNaughtonNo dataChecked brushes. Stiff but functional.All ok in redler.

2021 Maintenance - Preventative

11-Feb-21WPCAsset-00393OtherPenetrationPreventativeClean and InspectAndrew MacNaughtonNo dataChecked 3 or 11. Checked most fouled. All flowing ok. No plugging on 3 checked.Inspected numbers.
11-Feb-21WPCAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataAll Good.Tested
11-Feb-21WPCAsset-0239SizerM1430PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataChecked screens and noticed tears in oversized and target sized screens.
09-Feb-21WPCAsset-00394InstrumentationLT1210PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataNo data
05-Feb-21WPCAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataAll entered
04-Feb-21WPCAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased fittings
04-Feb-21WPCAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataAll okay
29-Jan-21WPCAsset-00376OtherWatertrax DataPreventativeVerificationOperators Waste Water PlantNo dataNo dataEntered
26-Jan-21WPCAsset-00380BuildingRaw Sludge (Building)PreventativeOperationalOperators Waste Water PlantNo dataNo dataExercised all applicable valves in raw sludge building
26-Jan-21WPCAsset-0014Bar Screenscreen2PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased bearings. Re route 1 grease line for efficient greasing
26-Jan-21WPCAsset-0013Bar Screenscreen1PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased bearings. Re route 1 grease line for more efficient greasing
26-Jan-21WPCAsset-0000WWTPWPCPPreventativeAlarm TestingOperators Waste Water PlantNo dataNo dataNo data
26-Jan-21WPCAsset-00381OtherWeirs (Primary Tanks)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataNot required. Not completed.
26-Jan-21WPCAsset-00384OtherWeirs (Secondary Tank)PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataNot required.
26-Jan-21WPCAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataRan. Tested. All good.
25-Jan-21WPCAsset-00407Belt PressBelt Press Roller BearingsPreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased all belt press roller bearings

2021 Maintenance - Preventative

25-Jan-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased stuffing box
20-Jan-21WPCPAsset-0192UV LampsUV632PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataRacks #1-9 inspected, greased and Acti-clean gel refreshed and topped up
19-Jan-21WPCPAsset-0249UV LampsUV631PreventativeClean and InspectOperators Waste Water PlantNo dataAll ok, and in service.All semi annual maintenance complete.
14-Jan-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataGreased
12-Jan-21WPCPAsset-00390GeneratorDiesel GeneratorPreventativeOperationalOperators Waste Water PlantNo dataNo dataRun, not under load.
12-Jan-21WPCPAsset-00412InstrumentationLAB Spectro WPCP onPreventativeVerificationOperators Waste Water PlantNo dataNo dataNo data
08-Jan-21WPCPAsset-00415AlarmFire Alarm SystemPreventativeOperationalAndrew MacNaughtonNo dataDetectors showing age as original. Alarms active in all buildings, and system operational.All ok
07-Jan-21WPCPAsset-00393OtherPelletcyclonePreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll have been checked, broken diaphragm on #2 which has been replaced. Replaced 1 muffler
06-Jan-21WPCPAsset-00401PumpM3020PreventativeClean and InspectOperators Waste Water PlantNo dataNo dataAll okay

APPENDIX D

Solids Handling


Town of Smiths Falls 2021 Performance Assessment Report - WPCP Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

2021 Pelletizer Production

MonthRun Time (hrs)Sludge Processed (m3)Total Number of Pellet bags filledTotal Number of Pellets Produced (kg)
January267.21,782.748.035,708.0
February221.41,584.548.033,632.0
March210.31,327.344.031,365.5
April151.91,095.936.024,899.0
May170.81,327.243.027,887.5
June224.81,698.047.031,429.5
July224.01,581.350.033,033.0
August186.71,384.846.031,108.0
September167.31,148.736.023,686.5
October186.91,240.939.025,800.0
November213.51,442.944.028,183.5
December191.51,349.723.015,438.5
Total2,416.316,964.0504.0342,171.0

$$ (m^{3}) $$

Pelletizer Production 2017 to 2021

YearRun Time HoursSludge Processed cubic metersTotal Number of Pellet bags filledTotal Number of Pellets Produced kgTotal Number of Pellets Produced (Tonnes)
20172,464.014,758.9628.0453,370.0453.4
20182,564.515,378.9614.0427,256.0427.3
20192,373.115,496.5653.0458,941.8458.9
20202,469.217,216.1492.0358,891.2358.9
20212,416.316,964.0504.0342,171.0342.2

Note: The weight of the pellets depends on the bulk density of the pellets. The bulk density changes depending on how the pellets are processed (i.e.temperature during processing, amount of poly used etc.). This is why sometimes there is more sludge processed but a lighter pellet weight.


Smiths Falls WPCP Yearly Solids Handling 2017 to 2021

YearTotal Number of Pellets Produced (Tonnes)Sludge Processed (m3, rhs)
201745314950
201842715450
201945815480
202035817180
202134116930

APPENDIX E

2021 Municipal Utility Monitoring Program (MUMPS)


Fields marked with an asterisk <sup>*</sup> are mandatory.

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *MonthYearDaysDischarge TypeUpdate Code
461200MonthYearDaysDischarge TypeUpdate Code0890
1231200111612021312R60

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON-OntarioPostal Code K7A5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
File No.4612000890MonthDaysDischarge TypeUpdate CodeYear
1231619312R
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total (mg/L)000514
1213Conductivity 25°C (μS/cm)910044
1213E. Coli (CT/100ml)9100041.00004
1213Nitrate, Unfiltered reactive (mg/L)000224
1213Nitrite, Unfiltered reactive (mg/L)000214
1213Nitrite, Unfiltered reactive (mg/L)000214
pH807704
Temperature, Water(℃)8025047.200011
Un-ionized Ammonia(mg/L)9101240.00305
Dissolved Oxygen(mg/L)000034
Hydrogen Sulphide(mg/L)830084
pH min8077047.080011
pH max8077047.740011
30343538
Operator Telephone NumberReturn completed form to:
Operator Email Address1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And
Comments2. Your Environmental Officer at your local District/Area MECP Office. (Find your local MECP office: https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)

Fields marked with an asterisk (*) are mandatory.

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
File No.12000089MonthYear28Discharge TypeUpdate Code
460220212R
1231620212280
C.P.
01FlowsParameter CodeDec.Monthly Results
1213Total Flow(103 m3)500103173.434
Average Daily Flow(103 m3/d)5001536.194
Maximum Daily Flow(103 m3/d)5002037.991
26Bypass30343538# of Occurrences
1213Plant Bypass Volume(103 m3)5002630
Duration(hours)805631
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage
1213BOD5(mg/L)0000101444
Suspended Solids(mg/L)0000601909
TKN(mg/L)00020219.904
Total Phosphorus(mg/L)0003312.98
04Final Effluent
1213BOD5(mg/L)0000113.04
CBOD5(mg/L)0000213.04
Suspended Solids(mg/L)0000610.613
Ammonia + Ammonium(mg/L)0001920.045
TKN(mg/L)0002020.804
Total Phosphorus(mg/L)0003320.0413
07Disinfection 12Chlorine Used Chlorine Dosage Chlorine Residual(kg as Cl2) (mg/L as Cl2) (mg/L as Cl2)50100 80410 804201 1 1 3438
Operator Telephone Number 613-283-4124Return completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Operator Email Address * scooke@smithsfalls.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Comments UV disinfectionMinistry Contact Email Address * brenda.beaudolin@ontario.ca

2062E (2020/10) Queen's Printer for Qntario, 2020


R2

Facility Address
Unit NumberStreet Number180Street NameQueen StreetPO Box
Municipality/City/TownTown of Smiths FallsProvinceON- OntarioPostal CodeK7A5B8
Operating AuthorityTown of Smiths Falls
Mailing Address
Unit NumberStreet Number77Street NameBeckwith StreetPO Box695
Municipality/City/TownTown of Smiths FallsProvinceON-OntarioPostal CodeK7A4T6
File No.Works Number*Data Period*MonthYearDaysDischargeTypeUpdateCode
461200000890022021282R
12311161920212280
C.P.Raw SewageParameter CodeDecMonthly Average Results# of Samples
03Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total(mg/L)000514
1213Conductivity 25℃(μS/cm)910044
1213E. Coli(CT/100ml)9100041.00004
1213Nitrate, Unfiltered reactive(mg/L)000224
1213Nitrite, Unfiltered reactive(mg/L)000214
1213Nitrite, Unfiltered reactive (mg/L)000214
pH8077047.350010
Temperature, Water(℃)8025047.200010
Un-ionized Ammonia(mg/L)9101240.00005
Dissolved Oxygen(mg/L)000034
Hydrogen Sulphide(mg/L)830084
pH min8077047.120010
pH max8077047.620010
Operator Telephone NumberReturn completed form to:
Operator Email Address1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And2. Your Environmental Officer at your local District/Area MECP Office.(Find your local MECP office:https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
Comments

Fields marked with an asterisk (*) are mandatory.

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
File No.Works Number *MonthYear312R
4612000890212280
1231116192021
C.P.
01FlowsParameter CodeDec.Monthly Results
1213Total Flow(103 m3)500103361.559
Average Daily Flow(103 m3)/d50015311.663
Maximum Daily Flow(103 m3)/d50020321.580
26Bypass30343538
1213Plant Bypass Volume(103 m3)500263
Duration(hours)805631
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage30343538
1213BOD5(mg/L)001055
Suspended Solids(mg/L)0018912
TKN(mg/L)0015.705
Total Phosphorus(mg/L)002.611
04Final Effluent30343538
1213BOD5(mg/L)003.05
CBOD5(mg/L)003.05
Suspended Solids(mg/L)000.913
Ammonia + Ammonium(mg/L)000.026
TKN(mg/L)000.705
Total Phosphorus(mg/L)000.0413
07Disinfection30343538
1213Chlorine Used(kg as Cl2)501001
Chlorine Dosage(mg/L as Cl2)804101
Chlorine Residual(mg/L as Cl2)804201
Operator Telephone Number 613-283-412430343538
Operator Email Address * scooke@smithsfalls.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office. Ministry Contact Email Address * brenda.beaudoin@ontario.ca
Comments UV disinfectionReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office. Ministry Contact Email Address * brenda.beaudoin@ontario.ca

2062E (2020/10) © Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet NumberStreet NamePO Box
Unit Number180Queen StreetPO Box
Municipality/City/TownProvincePostal Code
Town of Smiths FallsON - OntarioK7A5B8
Unit Number Municipality/City/Town Town of Smiths Falls File No. 4Street Number 77 Municipality/City/Town Town of Smiths Falls Works Number * 6Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 1Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 2Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 0Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 0Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 0Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 0Street Name Beckwith Street Municipality/City/Town Town of Smiths Falls Works Number * 8Street Name Beckwith Street Province ON - Ontario Data Period * Month 9Street Name Beckwith Street Province ON - Ontario Data Period * Month 0Street Name Beckwith Street Province ON - Ontario Year 0Street Name Beckwith Street Province ON - Ontario Year 3Street Name Beckwith Street Province ON - Ontario Year 2Street Name Beckwith Street Province ON - Ontario Year 0Street Name Beckwith Street Province ON - Ontario Days 2PO Box 695 Province ON - Ontario Days 1PO Box 695 Postal Code K7A4T6 Discharge Type 3PO Box 695 Postal Code K7A4T6 Update Code 1PO Box 695 Postal Code K7A4T6 R 2
12311161920212280
C.P. 0C.P. 3Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total (mg/L)000514
1213Conductivity 25°C (µS/cm)910044
1213E. Coli (CT/100ml)9100041.00005
1213Nitrate, Unfiltered reactive (mg/L)000224
1213Nitrite, Unfiltered reactive (mg/L)000214
1213pH8077047.210012
1213Temperature, Water (°C)8025046.500012
1213Un-ionized Ammonia (mg/L)9101240.00006
1213Dissolved Oxygen (mg/L)000034
1213Hydrogen Sulphide (mg/L)830084
1213pH min8077047.000012
1213pH max8077047.350012
1213
1213
1213
1213
  1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And

  2. Your Environmental Officer at your local District/Area MECP Office. (Find your local MECP office: https:// www.ontario.ca/environment-and-energy/ministry environment-district-locator)


R1

Fields marked with an asterisk $ ^{(\cdot)} $ are mandatory.

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 160Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
46120000890302R
12311161920212280
C.P.
01FlowsParameter CodeDecMonthly Results
1213Total Flow(103 m3)500103261.058
Average Daily Flow(103 m3)/d5001538.702
Maximum Daily Flow(103 m3)/d50020316.765
26Bypass30343538
1213Plant Bypass Volume(103 m3)500263# of Occurrences
Duration(hours)8056310
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage30343538
1213BOD5(mg/L)01604
Suspended Solids(mg/L)021310
TKN(mg/L)019.704
Total Phosphorus(mg/L)02.88
04Final Effluent30343538
1213BOD5(mg/L)03.04
CBOD5(mg/L)03.04
Suspended Solids(mg/L)00.912
Ammonia + Ammonium(mg/L)00.015
TKN(mg/L)00.804
Total Phosphorus(mg/L)00.0412
07Disinfection30343538
1213Chlorine Used(kg as Cl2)501001
Chlorine Dosage(mg/L as Cl2)804101
Chlorine Residual(mg/L as Cl2)804201
Operator Telephone Number 613-283-412430343538
Operator Email Address * scooke@smithsfalls.caReturn completed form to:
Comments UV disinfection1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office. Ministry Contact Email Address * brenda.beaudoin@ontario.ca

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A4T6
File No.Works Number *Data Period * Month YearDaysDischarge TypeUpdate Code
412000890302R
12300089016202180

Fields marked with an asterisk ( <sup>*</sup> ) are mandatory.

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
File No.Works Number *MonthYear31Discharge TypeUpdate Code
461200008900520212
123111620212280
C.P.
01FlowsParameter CodeDecMonthly Results
1213Total Flow(103 m3)500103276.714
Average Daily Flow(103 m3/d)5001538.926
Maximum Daily Flow(103 m3/d)50020315.909
26Bypass30343538
1213Plant Bypass Volume(103 m3)500263# of Occurrences
Duration(hours)8056310
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage
1213BOD5(mg/L)0000101264
Suspended Solids(mg/L)00006019212
TKN(mg/L)00020215.704
Total Phosphorus(mg/L)0003312.88
04Final Effluent30343538
1213BOD5(mg/L)0000113.04
CBOD5(mg/L)0000213.04
Suspended Solids(mg/L)0000610.514
Ammonia + Ammonium(mg/L)0001920.065
TKN(mg/L)0002020.704
Total Phosphorus(mg/L)0003320.0313
Operator Telephone Number 613-283-4124Return completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Operator Email Address * scooke@smithsfalls.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Comments UV disinfection Ministry Contact Email Address * brenda.beaudoin@ontario.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet NumberStreet NamePO Box
Unit Number180Queen StreetPO Box
Municipality/City/TownProvincePostal Code
Town of Smiths FallsON - OntarioK7A5B8
Operating Authority
Town of Smiths Falls
Mailing Address
Unit NumberStreet NumberStreet NamePO Box
Unit Number77Beckwith Street695
Municipality/City/TownProvincePostal Code
Town of Smiths FallsON - OntarioK7A4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
4612000890052021
312
C.P.
03Raw SewageParameter CodeMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total (mg/L)000514
1213Conductivity 25°C (µS/cm)910044
1213E. Coli (CT/100ml)9100041.00004
1213Nitrate, Unfiltered reactive (mg/L)000224
1213Nitrite, Unfiltered reactive (mg/L)000214
1213pH8077047.350011
1213Temperature, Water (°C)8025048.300011
1213Un-ionized Ammonia (mg/L)9101240.04005
1213Dissolved Oxygen (mg/L)000034
1213Hydrogen Sulphide (mg/L)830084
pH min8077047.220011
pH max8077047.460011
Operator Telephone Number 613-283-4124Return completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office. (Find your local MECP office: https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
Operator Email Address scooke@smithsfails.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office. (Find your local MECP office: https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
Comments Unable to include loadings not enough spaceReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office. (Find your local MECP office: https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)

Fields marked with an asterisk <sup>*</sup> are mandatory.

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 476
File No.Works Number *MonthYearDaysDischarge TypeUpdate Code
461200MonthYearDaysDischarge TypeUpdate Code0890
123120001302R

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths Falls
File No.Data Period * Month YearDaysDischarge TypeUpdate Code
4612000890021302R
1231111618192021222222222222

Fields marked with an asterisk ( <sup>*</sup> ) are mandatory.

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
File No.12000089MonthYear31Discharge TypeUpdate Code
46300000007202122R80
1230000001672021202180
C.P.
01FlowsParameter CodeDec.Monthly Results
1213Total Flow(103 m3)500103194.272
Average Daily Flow(103 m3/d)5001536.267
Maximum Daily Flow(103 m3/d)5002039.087
26Bypass30343538# of Occurrences
1213Plant Bypass Volume(103 m3)5002630
Duration(hours)805631
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage
1213BOD6(mg/L)0000101484
Suspended Solids(mg/L)00006025311
TKN(mg/L)00020223.104
Total Phosphorus(mg/L)0003313.610
04Final Effluent30343538
1213BOD5(mg/L)0000113.04
CBOD6(mg/L)0000213.04
Suspended Solids(mg/L)0000610.714
Ammonia + Ammonium(mg/L)0001920.025
TKN(mg/L)0002020.704
Total Phosphorus(mg/L)0003320.0414
Operator Telephone Number 613-283-4124Return completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Operator Email Address * scooke@smithsfalls.caMinistry Contact Email Address * brenda.beaudoin@ontario.ca
Comments UV disinfectionMinistry Contact Email Address * brenda.beaudoin@ontario.ca

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet Number180Street NameQueen StreetPO Box
Municipality/City/TownTown of Smiths FallsProvinceON- OntarioPostal CodeK7A5B8
Operating AuthorityTown of Smiths Falls
Mailing Address
Unit NumberStreet Number77Street NameBeckwith StreetPO Box695
File No.Works Number*Data Period*Days31Discharge TypeUpdate Code
4612000890MonthYearDays31Discharge TypeUpdate Code
1231619202122R
C.P.Raw SewageParameter CodeDecMonthly Average Results# of Samples
03Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total(mg/L)000514
1213Conductivity 25°C(μS/cm)910044
E. Coli(CT/100ml)9100041.00004
Nitrate, Unfiltered reactive(mg/L)000224
Nitrite, Unfiltered reactive(mg/L)000214
pH8077047.340010
Temperature, Water(℃)80250411.900010
Un-ionized Ammonia(mg/L)9101240.01005
Dissolved Oxygen(mg/L)000034
Hydrogen Sulphide(mg/L)830084
pH min8077047.180010
pH max8077047.340010
30343538
Operator Telephone Number613-283-4124Return completed form to:
Operator Email Addressscooke@smithsfalls.ca1. Environmental Monitoring and Reporting Branch, MECP, atWasteWaterReporting@ontario.caAnd2. Your Environmental Officer at your local District/AreaMECP Office.(Find your local MECP office:https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
CommentsUnable to include loadings not enough space

Fields marked with an asterisk (*) are mandatory.

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *MonthYearDaysDischarge TypeUpdate Code
412000MonthYearDaysDischarge TypeUpdate Code890
1230001116202131R
C.P.
01FlowsParameter CodeDecMonthly Results
1213Total Flow (10³ m³)500103184.615
Average Daily Flow (10³ m³/d)5001535.955
Maximum Daily Flow (10³ m³/d)5002039.009
30343538
26Bypass500263# of Occurrences
1213Plant Bypass Volume (10³ m³)8056310
Duration (hours)805631
Secondary Bypass Volume (10³ m³)500403
Duration (hours)805651
03Raw Sewage000010153
1213BOD₅ (mg/L)000060255
Suspended Solids (mg/L)00020224.60
TKN (mg/L)0003312.3
Total Phosphorus (mg/L)0003312.3
04Final Effluent0000113.0
1213BOD₆ (mg/L)0000213.0
CBOD₆ (mg/L)0000610.7
Suspended Solids (mg/L)0001920.01
Ammonia + Ammonium (mg/L)0002020.70
TKN (mg/L)0002020.06
Total Phosphorus (mg/L)0003320.06
07Disinfection501001
1213Chlorine Used (kg as Cl₂)804101
Chlorine Dosage (mg/L as Cl₂)804201
Chlorine Residual (mg/L as Cl₂)804201
Operator Telephone Number 613-283-4124
Operator Email Address * scooke@smithsfalls.ca
Comments UV disinfection

2062E (2020/10) © Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A5B8
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A4T6
File No.Works Number *Data Period * MonthYearDaysDischarge TypeUpdate CodeR
461200008900820213122 80
123112021
C.P.
03Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total (mg/L)000514
1213Conductivity 25°C (µS/cm)910044
1213E. Coli (CT/100ml)9100041.00004
1213Nitrate, Unfiltered reactive (mg/L)000224
1213Nitrite, Unfiltered reactive (mg/L)000214
1213pH8077047.230010
1213Temperature, Water (°C)80250411.800010
1213Un-ionized Ammonia (mg/L)9101240.00005
1213Dissolved Oxygen (mg/L)000034
1213Hydrogen Sulphide (mg/L)830084
1213pH min8077046.950010
1213pH max8077047.410010
1213
1213
1213
1213
Operator Telephone Number 613-283-4124
Operator Email Address scooke@smithsfalls.ca
Comments Unable to include loadings not enough space
  1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And

  2. Your Environmental Officer at your local District/Area MECP Office. (Find your local MECP office: https:// www.ontario.ca/environment-and-energy/ministry environment-district-locator)


Fields marked with an asterisk (*) are mandatory. Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5BB
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
4612000092021
123111619202122
C.P.
01FlowsParameter CodeNo.Monthly Results
1213Total Flow(103 m3)500103195.816
Average Daily Flow(103 m3)/d5001536.527
Maximum Daily Flow(103 m3)/d50020311.507
26Bypass30343538
1213Plant Bypass Volume(103 m3)500263# of Occurrences
Duration(hours)8056310
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage30343538
1213BOD5(mg/L)000010187# of Samples
Suspended Solids(mg/L)0000603225
TKN(mg/L)00020224.007
Total Phosphorus(mg/L)0003315.55
04Final Effluent30343538
1213BOD5(mg/L)0000113.05
CBOD5(mg/L)0000213.05
Suspended Solids(mg/L)0000610.59
Ammonia + Ammonium(mg/L)0001920.026
TKN(mg/L)0002020.705
Total Phosphorus(mg/L)0003320.0510
07Disinfection30343538
1213Chlorine Used(kg as Cl2)501001
Chlorine Dosage(mg/L as Cl2)804101
Chlorine Residual(mg/L as Cl2)804201
Operator Telephone Number30343538
613-283-4124
Operator Email Address *
scooke@smithsfalls.ca
Comments
UV disinfection, revised to correct pH max

R2

Facility Address
Unit NumberStreet Number180Street NameQueen StreetPO Box
Municipality/City/TownTown of Smiths FallsProvinceON-OntarioPostal CodeK7A5B8
Operating AuthorityTown of Smiths Falls
Mailing Address
Unit NumberStreet Number77Street NameBeckwith StreetPO Box695
Municipality/City/TownTown of Smiths FallsProvinceON-OntarioPostal CodeK7A4T6
File No.Works Number*Data Period*MonthYearDaysDischargeTypeUpdateCode
461200000890110920211619202122R80
C.P.
03Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
1213
1213
1213
1213
1213
1213
1213
1213
1213
1213
121304Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total(mg/L)000514
1213Conductivity 25°C(μS/cm)910044
1213E. Coli(CT/100ml)9100041.00005
Nitrate, Unfiltered reactive (mg/L)000224
Nitrite, Unfiltered reactive (mg/L)000214
pH8077047.46009
Temperature, Water(℃)8025049.50009
Un-ionized Ammonia(mg/L)9101240.04006
Dissolved Oxygen(mg/L)000034
Hydrogen Sulphide(mg/L)830084
pH min8077047.30009
pH max8077047.74009
Operator Telephone Number613-283-4124Return completed form to:1.Environmental Monitoring and Reporting Branch,MECP,atWasteWaterReporting@ontario.caAnd2.Your Environmental Officer at your local District/AreaMECP Office.(Find your local MECP office:https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
Operator Email Addressscooke@smithsfalls.ca
CommentsUnable to include loadings not enough space

Fields marked with an asterisk $ ^{(\star)} $ are mandatory.

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths Falls
File No. Works Number *Data Period * Month YearDaysDischarge Type Update Code
4612000890312R
123100089016192021
C.P.
01FlowsParameter CodeDec.Monthly Results
1213Total Flow (10³ m³)500103250,789
Average Daily Flow (10³ m³/d)5001538,090
Maximum Daily Flow (10³ m³/d)50020318,641
26Bypass30343538# of Occurrences
1213Plant Bypass Volume (10³ m³)5002630
Duration (hours)805631
Secondary Bypass Volume (10³ m³)500403
Duration (hours)805651
03Raw Sewage30343538# of Samples
1213BCD₆ (mg/L)0000101364
Suspended Solids (mg/L)0000601997
TKN (mg/L)00020218.404
Total Phosphorus (mg/L)0003313.46
04Final Effluent30343538# of Samples
1213BOD₅ (mg/L)0000113.04
CBCD₆ (mg/L)0000213.04
Suspended Solids (mg/L)0000610.511
Ammonia + Ammonium (mg/L)0001920.025
TKN (mg/L)0002020.604
Total Phosphorus (mg/L)0003320.0512
07Disinfection30343538# of Samples
1213Chlorine Used (kg as Cl₂)501001
Chlorine Dosage (mg/L as Cl₂)804101
Chlorine Residual (mg/L as Cl₂)804201
Operator Telephone Number 613-283-4124
Operator Email Address * scooke@smithsfalls.ca
Comments UV disinfection

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Facility Address
Unit NumberStreet Number180Street NameQueen StreetPO Box
Municipality/City/TownTown of Smiths FallsProvinceON- OntarioPostal CodeK7A5B8
Operating AuthorityTown of Smiths Falls
Mailing Address
Unit NumberStreet Number77Street NameBeckwith StreetPO Box695
Municipality/City/TownTown of Smiths FallsProvinceON-OntarioPostal CodeK7A4T6
File No.Works Number*Data Period*MonthYearDaysDischargeTypeUpdateCode
461200000890111619202122R80
C.P.
03Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total(mg/L)000514
1213Conductivity 25℃(μS/cm)910044
1213E. Coll(CT/100ml)9100041.00004
1213Nitrate, Unfiltered reactive(mg/L)000224
1213Nitrite, Unfiltered reactive(mg/L)000214
1213pH8077047.330010
Temperature,Water(℃)(℃)8025047.80007
Un-ionized Ammonia(mg/L)(mg/L)9101240.01005
Dissolved Oxygen(mg/L)(mg/L)000034
Hydrogen Sulphide(mg/L)(mg/L)830084
pHmin8077047.010010
pHmax8077047.550010
Operator Telephone Number613-283-4124Return completed form to:
Operator Email Addressscooke@smithsfalls.ca1.Environmental Monitoring and Reporting Branch,MECP,atWasteWaterReporting@ontario.caAnd2.Your Environmental Officer at your local District/AreaMECP Office.(Find your local MECP office:https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
CommentsUnable to include loadings not enough space

Fields marked with an asterisk <sup>*</sup> are mandatory.

Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
File No.Works Number *MonthYear30Discharge TypeUpdate Code
461200008901120212
1231612021202180
C.P.
01FlowsParameter CodeDec.Monthly Results
1213Total Flow(103 m3)500103234.813
Average Daily Flow(103 m3/d)5001537.827
Maximum Daily Flow(103 m3/d)50020310.541
26Bypass30343538# of Occurrences
1213Plant Bypass Volume(103 m3)5002630
Duration(hours)805631
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage# of Samples
1213BOD5(mg/L)0000101464
Suspended Solids(mg/L)00006019919
TKN(mg/L)00020217.904
Total Phosphorus(mg/L)0003313.66
04Final Effluent30343538
1213BOD5(mg/L)0000113.04
CBOD5(mg/L)0000213.04
Suspended Solids(mg/L)0000610.914
Ammonia + Ammonium(mg/L)0001920.056
TKN(mg/L)0002020.704
Total Phosphorus(mg/L)0003320.0513
Operator Telephone Number 613-283-4124Return completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Operator Email Address * scooke@smlthsfalls.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.
Comments UV disinfection Ministry Contact Email Address * brenda.beaudoin@ontario.caReturn completed form to: 1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And 2. Your Environmental Officer at your local District/Area MECP Office.

2062E (2020/10) Queen's Printer for Ontario, 2020


R2

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON-OntarioPostal Code K7A5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number77Street NameBeckwith StreetPO Box695
Municipality/City/TownTown of Smiths FallsProvinceON-OntarioPostal CodeK7A4T6
File No.Works Number*Data Period*MonthYearDaysDischargeTypeUpdateCode
46120000089013111619202122R80
12320212280
C.P.
03Raw SewageParameter CodeDecMonthly Average Results# of Samples
1213
04Final EffluentParameter CodeDecMonthly Average Results# of Samples
1213Alkalinity, Total (mg/L)000514
1213Conductivity 25℃(μS/cm)910044
1213E. Coli(CT/100ml)9100041.00004
1213Nitrate, Unfiltered reactive(mg/L)000224
1213Nitrite, Unfiltered reactive(mg/L)000214
1213Nitrite, Unfiltered reactive (mg/L)000214
pH8077047.460011
Temperature, Water(℃)8025048.700010
Un-lonized Ammonia(mg/L)9101240.01004
Dissolved Oxygen(mg/L)000034
Hydrogen Suiphide(mg/L)830084
pH min8077047.210011
pH max8077047.970011
30343538
Operator Telephone Number613-283-4124Return completed form to:
Operator Email Addressscooke@smithsfalls.ca1. Environmental Monitoring and Reporting Branch, MECP, atWasteWaterReporting@ontario.caAnd2. Your Environmental Officer at your local District/AreaMECP Office.(Find your local MECP office:https://www.ontario.ca/environment-and-energy/ministry-environment-district-locator)
CommentsUnable to include loadings not enough space

Fields marked with an asterisk $ ^{(\ast)} $ are mandatory.

Project Name Smiths Falls Water Pollution Control Plant
Facility Address
Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A 4T6
File No.Works Number *Data Period *DaysDischarge TypeUpdate Code
461200002132
1230016192021
C.P.
01FlowsParameter CodeDec.Monthly Results
1213Total Flow(103 m3)500103288.462
Average Daily Flow(103 m3/d)5001539.305
Maximum Daily Flow(103 m3/d)50020317.146
26Bypass30343538
1213Plant Bypass Volume(103 m3)500263# of Occurrences
Duration(hours)8056310
Secondary Bypass Volume(103 m3)500403
Duration(hours)805651
03Raw Sewage30343538
1213BOD6(mg/L)000010136# of Samples
Suspended Solids(mg/L)0000601725
TKN(mg/L)00020216.809
Total Phosphorus(mg/L)0003312.25
04Final Effluent30343538
1213BOD6(mg/L)0000113.05
CBOD5(mg/L)0000213.05
Suspended Solids(mg/L)0000610.612
Ammonia + Ammonium(mg/L)0001920.016
TKN(mg/L)0002020.705
Total Phosphorus(mg/L)0003320.0312
07Disinfection30343538
1213Chlorine Used(kg as Cl2)501001
Chlorine Dosage(mg/L as Cl2)804101
Chlorine Residual(mg/L as Cl2)804201
Operator Telephone Number 613-283-4124Return completed form to:
Operator Email Address * scooke@smithsfalls.ca1. Environmental Monitoring and Reporting Branch, MECP, at WasteWaterReporting@ontario.ca And
Comments2. Your Environmental Officer at your local District/Area MECP Office.
UV disinfectionMinistry Contact Email Address * brenda.beaudoin@ontario.ca

2062E (2020/10) $ \textcircled{c} $ Queen's Printer for Ontario, 2020


R2

Unit NumberStreet Number 180Street Name Queen StreetPO Box
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A5B8
Operating Authority Town of Smiths Falls
Mailing Address
Unit NumberStreet Number 77Street Name Beckwith StreetPO Box 695
Municipality/City/Town Town of Smiths FallsProvince ON - OntarioPostal Code K7A4T6
File No.Works Number *Data Period * MonthYearDaysDischarge TypeUpdate Code
46120Data Period * MonthYearDaysDischarge TypeUpdate Code00890122021312R80
12311161920212280

APPENDIX F

Operators Licenses


Wastewater Operator Licenses

Smiths Falls Water Polluction Control Plant Class 4 Works # 120000890 Conventional Tertiary Treatment UV Disinfection / Pelletization

OperatorOperator IDClassLicense #Expiry Date (DD/MM/YY)TypeORO/ OIC
Jason Barlow9001098741244830-Apr-22WWTORO
Steve Laplante9000122241335831-Jan-24WWTOIC/ORO alternative
Tyler George9005401246824031-Jan-25WWTOIC/ORO alternative
Andrew MacNaughton9005313549261730-Apr-24WWTOIC
Molly Buckland90087406211208430-Apr-24WWTOIC
Aaron Morris90073911110819631-Dec-22WWT
Other Departments
Sarah E. Cooke90010541OIT4274030-Sep-24WWTN/A
Harrison Leithch90086060OITOT10239930-Sep-24WWTN/A

APPENDIX G

Notice of Modifications to Sewage Works


Notice of Modification to Sewage Works

RETAIN COPY OF COMPLETED FORM AS PART OF THE ECA ON-SITE PRIOR TO THE SCHEDULED IMPLEMENTATION DATE.

Part 1 – Environmental Compliance Approval (ECA) with Limited Operational Flexibility (Insert the ECA’s owner, number and issuance date and notice number, which should start with “01” and consecutive numbers thereafter)
ECA Number #5671-AE7HFTIssuance Date (mm/dd/yy) 03/16/21Notice number (if applicable) 4
ECA Owner Town of Smiths FallsMunicipality Town of Smiths Falls

Part 2: Description of the modifications as part of the Limited Operational Flexibility
(Attach a detailed description of the sewage works)

Supply and configuration of the Win 911 software for the Wastewater Treatment Plant (WWTP).

The software will be installed on each SCADA computer as a hot back up pair. One system will be kept on standby mode and activated upon server failover.

The existing Raco Dialer will be used as backup response system if no response is received within a certain time will need to make modifications in the existing PLC program to give the operator to acknowledge alarms in Win 911 first.

Software:

WIN-911/Interactive licences

Includes 2-way communication with all notifiers: SMS, Email, Voice, and 10 Smartphone Apps. Includes Announcer.

Allows for remote acknowledgments, alarm requests, report requests. Includes one year WIN-911 Customer Care Subscription.

WIN-911/Interactive-HB, Interactive Hot Backup.

WIN-911 Premium Voice - US English.

WIN-911 Premium Voice - US English HOT BACKUP

2 x Grandstream VoIP PBX for up to 2 analog voice line connections.

Description shall include:

  1. A detail description of the modifications and/or operations to the sewage works (e.g. sewage work component, location, size, equipment type/model, material, process name, etc.)
  2. Confirmation that the anticipated environmental effects are negligible.
  3. List of updated versions of, or amendments to, all relevant technical documents that are affected by the modifications as applicable, i.e. submission of documentation is not required, but the listing of updated documents is (design brief, drawings, emergency plan, etc.)
Part 3 – Declaration by Professional Engineer
I hereby declare that I have verified the scope and technical aspects of this modification and confirm that the design: 1. Has been prepared or reviewed by a Professional Engineer who is licensed to practice in the Province of Ontario; 2. Has been designed in accordance with the Limited Operational Flexibility as described in the ECA; 3. Has been designed consistent with Ministry’s Design Guidelines, adhering to engineering standards, industry’s best management practices, and demonstrating ongoing compliance with s.53 of the Ontario Water Resources Act; and other appropriate regulations. I hereby declare that to the best of my knowledge, information and belief the information contained in this form is complete and accurate
Name (Print)PEO License Number
SignatureDate (mm/dd/yy)
Name of Employer

Page 1 of 2


Part 4 – Declaration by Owner
I hereby declare that:1. I am authorized by the Owner to complete this Declaration;2. The Owner consents to the modification; and3. This modifications to the sewage works are proposed in accordance with the Limited Operational Flexibility as described in the ECA.4. The Owner has fulfilled all applicable requirements of the Environmental Assessment Act.I hereby declare that to the best of my knowledge, information and belief the information contained in this form is complete and accurate
Name of Owner Representative (Print)Jason BarlowOwner representative's title (Print)Manager Water/Wastewater Treatment
Owner Representative's SignatureDate (mm/dd/yy)04/09/21

EAPB Form July 26, 2018

Page 2 of 2


RETAIN COPY OF COMPLETED FORM AS PART OF THE ECA ON-SITE PRIOR TO THE SCHEDULED IMPLEMENTATION DATE.

Part 1 – Environmental Compliance Approval (ECA) with Limited Operational Flexibility (Insert the ECA's owner, number and issuance date and notice number, which should start with "01" and consecutive numbers thereafter)
ECA Number #5671-AE7HFTIssuance Date (mm/dd/yy) January 11, 2017Notice number (if applicable) 04 Noticed number should be #5
ECA Owner The Corporation of the Separated Town of Smiths FallsMunicipality Town of Smiths Falls

Part 2: Description of the modifications as part of (Attach a detailed description of the sewage works)

the Limited Operational Flexibility

Supply and configuration of updated PLC equipment and s modifications will include:

ware for the Water Pollution Control Plant (WPCP). The

  • Replacement of the existing Bristol-Babcock (BB) controllers (5 of) with Allen-Bradley devices. o BB Controllers in Headworks, Blower, and Tertiary Treatment process units to be replaced with PLC's. New PLC's to be programmed with existing control logic. o BB Controller in Pelletizer process unit to be replaced with remote I/O.

  • Replacements of the existing SCADAPACK 32 controllers (3 of) with Allen-Bradley PLC's. o Replace existing Allen-Bradley ControlLogix PLC's, Provide new PLC control panel (CP-100) in Headworks process unit.

Provide new PLC control panel in Blower process unit (CP-400) and wiring to existing RPU-400

  • Modify existing control panels for controller replacements, touchscreen HMI additions, and general clean-up of panel layout (provision of wiring ducts/covers, routing of wiring, removal of obsolete wiring, etc).

  • Provision of a new development PC and all softwar for the Work.

licenses for SCADA/PLC/HMI programming development

  • The new works will include the required start-up, commissioning,and operator training services as well as As-Built wiring diagrams,O&M manuals,and software back-ups for all of the modifications and updates to the control systems.

We confirm that the anticipated environmental effects of the modifications are negligible, control redundancies are in place during the modifications and operations will be aware of the changes as they are brought on-line.

The technical documentation that are being updated as part of this work include the following list of network and controls drawings: a. C101 Existing Site Plan b. I011 Existing Network Topology c. I012 New Network Topology d. I021 Typical Control Panel – Layout Detail e. I022 Typical Control Panel – Wiring Details f. I101 Headworks Building – Control Panel Modifications g. I102 Headworks Building – PLC I/O Migration – 1 of 2 h. I103 Headworks Building – PLC I/O Migration – 2 of 2 i. I401 Blower Building – Control Panel Modifications j. I402 Blower Building – PLC I/O Migration k. I601 Tertiary Treatment Building – Control Panel Modifications l. I602 Tertiary Treatment Building – PLC I/O Migrations m. I701 CSO Tank Building – Control Panel Modifications n. I702 CSO Tank Building – Control System Wiring Details o. I801 Administration Building – Control Panel Modifications p. I901 Pelletizer Building – CP-900 & CP-901 Modifications q. I902 Pelletizer Building – CP-902 & Fibre Network Panel Modifications r. I903 Pelletizer Building – CP-902 Wiring Detail & RTU-902 I/O Migration s. I1001 OPP Pumping Station – Control Panel Modifications t. I1101 Centre St. Pumping Station – Control Panel Modifications


Part 3 – Declaration by Professional Engineer I hereby declare that I have verified the scope and technical aspects of this modification and confirm that the design: 1. Has been prepared or reviewed by a Professional Engineer who is licensed to practice in the Province of Ontario; 2. Has been designed in accordance with the Limited Operational Flexibility as described in the ECA; 3. Has been designed consistent with Ministry's Design Guidelines, adhering to engineering standards, industry's best management practices, and demonstrating ongoing compliance with s.53 of the Ontario Water Resources Act; and other appropriate regulations. I hereby declare that to the best of my knowledge, information and belief the information contained in this form is complete and accurate
Name (Print) Jamie BakerPEO License Number 100151897
SignatureDate (mm/dd/yy) December 20, 2021
Name of employer EVB Engineering
Part 4 – Declaration by Owner I hereby declare that: 1. I am authorized by the Owner to complete this Declaration; 2. The Owner consents to the modification; and 3. This modifications to the sewage works are proposed in accordance with the Limited Operational Flexibility as described in the ECA. 4. The Owner has fulfilled all applicable requirements of the Environmental Assessment Act. I hereby declare that to the best of my knowledge, information and belief the information contained in this form is complete and accurate
Name of Owner Representative (Print) Jason BarlowOwner representative's title (Print) Manager of Water/Wastewater Treatment
Owner Representative's SignatureDate (mm/dd/yy) December 20th, 2021

EAPB Form July 26, 2018